HUNTSVILLE, AL —
OSHA Inspection: ADVANCED SYSTEMS TECHNOLOGY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADVANCED SYSTEMS TECHNOLOGY, INC. in 165 ELECTRONICS BOULEVARD SOUTHWEST ATTN: JEFF FERGUSON, HUNTSVILLE, AL 35824 (NAICS 333111). OSHA activity number 345844781.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED SYSTEMS TECHNOLOGY, INC.
- Site address
- 165 ELECTRONICS BOULEVARD SOUTHWEST ATTN: JEFF FERGUSON
- City
- HUNTSVILLE
- State
- AL
- ZIP
- 35824
- Mailing
- 165 ELECTRONICS BOULEVARD SOUTHWEST, HUNTSVILLE, AL 35824
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 33
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 L01 I
- Issued
- Aug 19, 2022
- Abate by
- Sep 15, 2022
- Penalty
- Initial $8,702 · Current $5,221 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in 1910.178(l): (a) On or about 02/22/2022 and at times prior to - Shipping and Receiving area, employees operating forklifts and working in proximity to them were exposed to struck-by hazards due to 15 of the 15 operators not completing training and evaluation as required.
Recent events (2)
- — I (S) $5221.2
- — Z (S) $8702
1910.212 A01
- Issued
- Aug 19, 2022
- Abate by
- Sep 15, 2022
- Penalty
- Initial $10,151 · Current $6,091 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 02/22/2022, and at times prior to - 165 Southwest Electronics Boulevard, Huntsville, AL 35824 in the Drill Press/Milling Area, employees were exposed to amputation hazards due to unguarded rotating parts for the following machinery: (a) Ibarmia B-50 Drill Press (b) Rockwell 20-inch drill press; (c) Clausing Drill Press Model 20; (d) Powermatic Milling Machine.