Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OLDCASTLE BUILDINGENVELOPE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OLDCASTLE BUILDINGENVELOPE, INC. in 1101 FOUNTAIN PARKWAY, GRAND PRAIRIE, TX 75050 (NAICS 327215). OSHA activity number 345847362.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oldcastle Buildingenvelope, INC. — free Get an email when a new federal OSHA severe-injury report for Oldcastle Buildingenvelope, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1101 FOUNTAIN PARKWAY
City
GRAND PRAIRIE
State
TX
ZIP
75050
Mailing
1101 FOUNTAIN PARKWAY, GRAND PRAIRIE, TX 75050
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327215
Employees
162
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 2, 2022
Abate by
May 26, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or before March 21, 2022, employees cleaning sensors, changing out spacer material, and/or repairing or replacing the needle within the robotic head unit of the Lisec VSA-35/25 Fully Automated Applicator were exposed to a struck-by hazard when: (a) Specific hazardous energy control procedures were developed and documented but only listed one of the three energy sources that power the machine and did not include the blocking of the robotic head unit so it would not unexpectedly fall due to gravity. (b) Specific Hazardous energy control procedures were not being utilized in that employees relied on interlocks to shut down the machine and not locking it out.
Recent events (2)
  • — I (S) $14502
  • — Z (S) $14502

1910.147 C07 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 2, 2022
Abate by
May 26, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  (a) On or before March 21, 2022, the employer did not provide adequate training in that machine operators who are required to work on the Lisec VSA-35/25 Fully Automated Applicator are only trained as affected employees and not authorized employees thereby exposing them to a struck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

1910.147 D03

Serious Gravity 10 1 instance 2 exposed
Issued
May 2, 2022
Abate by
May 26, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) On or about March 21, 2022, while locking and tagging out the Lisec VSA-35/25 Fully Automated Applicator all energy isolating devices were not physically located and operated in such a manner as to isolate the VSA machine from the energy sources exposing employees working on it to a struck-by hazard.
Recent events (2)
  • — I (S) $14502
  • — Z (S) $14502

1910.147 D05 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 2, 2022
Abate by
May 26, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:  (a) On or about March 21, 2022, while locking and tagging out the Lisec VSA-35/25 Fully Automated Applicator all potentially hazardous stored or residual energy was not relieved, disconnected, restrained, or otherwise rendered safe after the application of lockout and tagout devices to energy isolating devices exposing employees working on it to a struck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

View Oldcastle Buildingenvelope, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345847362.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.