FORT BRAGG, NC —
OSHA Inspection: U.S. DEPT. OF ARMY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of U.S. DEPT. OF ARMY in BUILDING 2-1127, FORT BRAGG, NC 28310 (NAICS 928110). OSHA activity number 345847602.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPT. OF ARMY
- Site address
- BUILDING 2-1127
- City
- FORT BRAGG
- State
- NC
- ZIP
- 28310
- Mailing
- 2175 REILLY RD, FORT BRAGG, NC 28310
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 100
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.1001 J03 I
- Issued
- May 13, 2022
- Abate by
- Jun 6, 2022
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.1001(j)(3)(i): Building and facility owners shall determine the presence, location, and quantity of ACM and/or PACM at the work site. Employers and building and facility owners shall exercise due diligence in complying with these requirements to inform employers and employees about the presence and location of ACM and PACM. Building #2-1127, Room 217: On or about March 22, 2022, the employer did not ensure that all employees, including contractors, performing cyber security work were properly notified of the presence of asbestos containing material (ACM). The asbestos containing material had not been identified and the building/facility owner did not notify all prospective employers and employees of the risk of encountering ACM while working in the building. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $0
1910.1001 J05 I
- Issued
- May 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1001(j)(5)(i):Labeling. Labels shall be affixed to all raw materials, mixtures, scrap, waste, debris, and other products containing asbestos fibers, or to their containers. When a building owner or employer identifies previously installed ACM and/or PACM, labels or signs shall be affixed or posted so that employees will be notified of what materials contain ACM and/or PACM. The employer shall attach such labels in areas where they will clearly be noticed by employees who are likely to be exposed, such as at the entrance to mechanical room/areas. Signs required by paragraph (j) of this section may be posted in lieu of labels so long as they contain the information required for labeling. Building #2-1127, Room 217: On or about March 22, 2022, the employer did not ensure that all pipes inside the work space that was wrapped in asbestos thermal system insulation (TSI) were properly labeled or identifed for office employees engaged in cyber security operations. CORRECTED DURING INSPECTION
Recent events (1)
- — Z (S) $0
1910.1001 J07 IV
- Issued
- May 13, 2022
- Abate by
- Jun 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1001(j)(7)(iv): The employer shall also provide, at no cost to employees who perform housekeeping operations in an area which contains ACM or PACM, an asbestos awareness training course, which shall at a minimum contain the following elements: health effects of asbestos, locations of ACM and PACM in the building/facility, recognition of ACM and PACM damage and deterioration, requirements in this standard relating to housekeeping, and proper response to fiber release episodes, to all employees who perform housekeeping work in areas where ACM and/or PACM is present. Each such employee shall be so trained at least once a year. Building #2-1127, Room 217: On or about March 22, 2022, the employer did not ensure that all employees, including contractors, performing cyber security work and other activities, such as vacuuming, where damaged asbestos pipe insulation was present were trained in Class IV operations. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $0
More inspections at U.S. Dept. of Army
View U.S. Dept. of Army's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345847602.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.