COLUMBIANA, OH —
OSHA Inspection: COLUMBIANA BOILER COMPANY, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of COLUMBIANA BOILER COMPANY, LLC in 200 W. RAILROAD ST., COLUMBIANA, OH 44408 (NAICS 332999). OSHA activity number 345854152.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLUMBIANA BOILER COMPANY, LLC
- Site address
- 200 W. RAILROAD ST.
- City
- COLUMBIANA
- State
- OH
- ZIP
- 44408
- Mailing
- 200 W. RAILROAD ST., COLUMBIANA, OH 44408
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 38
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.95 B01
- Issued
- Aug 26, 2022
- Abate by
- Jan 30, 2023
- Penalty
- Initial $7,252 · Current $4,351 Reduced
General-duty citation text
29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible engineering controls were not utilized: (a) Columbiana Boiler Company, LLC, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: On or about May 25th, 2022, an employee working in the grinding booth was exposed to noise at 476.2% of the permissible daily dose, or an average sound level of 101.6 dBA, as measured over 455 minutes of monitoring. This dose is equivalent to an 8-hour TWA exposure of 101.2 dBA accounting for the period of 25 minutes unmonitored.
Recent events (3)
- — P (S) $4351
- — I (S) $4351
- — Z (S) $7252
1910.95 D01
- Issued
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(d)(1):When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: (a) Columbiana Boiler Company, LLC, on or about May 25th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: Employees were exposed to noise in excess of an 85 decibel 8-hour time-weighted average without the benefit of a monitoring program to identify and mitigate noise exposure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E02 II B 2
- Issued
- Aug 26, 2022
- Abate by
- Oct 14, 2022
- Penalty
- Initial $7,252 · Current $2,901 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b)(2):More than 120 gallons of Category 2, 3, or 4 flammable or combustible liquids in containers were located outside of inside storage room(s) or storage cabinet(s): (a) Columbiana Boiler Company, LLC, on or about March 24th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: The employer had approximately fifty-seven five-gallon buckets of a category 2 flammable paint in the painting area that was not contained in a storage room or storage cabinet.
Recent events (2)
- — I (S) $2901
- — Z (S) $7252
1910.134 C02 II
- Issued
- Aug 26, 2022
- Abate by
- Sep 22, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (a) Columbiana Boiler Company, LLC, on or about May 25th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: An employee was provided with a full-face elastomeric respirator without the benefit of established cleaning procedures to ensure it did not create an additional health hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $4351
1910.134 H01
- Issued
- Aug 26, 2022
- Abate by
- Sep 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(1):Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer: (a) Columbiana Boiler Company, LLC, on or about May 25th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: An employee was provided with a full-face elastomeric respirator which was not cleaned using appropriate procedures on a regular basis.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.252 B02 III
- Issued
- Aug 26, 2022
- Abate by
- Sep 22, 2022
- Penalty
- Initial $8,702 · Current $5,221 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: (a) Columbiana Boiler Company, LLC, on or about March 24th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: Employees were welding without utilizing weld screens or shields to protect adjacent employees from eye exposure.
Recent events (2)
- — I (S) $5221
- — Z (S) $8702
1910.1025 L01 I
- Issued
- Aug 26, 2022
- Abate by
- Sep 22, 2022
- Penalty
- Initial $4,351 · Current $4,351
1591
General-duty citation text
29 CFR 1910.1025(l)(1)(i):Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: (a) Columbiana Boiler Company, LLC, on or about May 25th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: An employee was exposed to lead at an 8-hour TWA of 0.006 milligrams per cubic meter without the benefit of having been informed of the content of appendices A and B of the general industry lead standard.
Recent events (2)
- — I (S) $4351
- — Z (S) $4351
1910.1025 M01 III
- Issued
- Aug 26, 2022
- Abate by
- Sep 22, 2022
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1910.1025(m)(1)(iii):Employers shall include lead in the hazard communication program established to comply with the HCS (� 1910.1200). Employers shall ensure that each employee has access to labels on containers of lead and to safety data sheets, and is trained in accordance with the requirements of HCS and paragraph (l) of this section. (a) Columbiana Boiler Company, LLC, on or about May 25th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: An employee was exposed to lead at an 8-hour TWA of 0.006 milligrams per cubic meter without the benefit of having included lead within the hazard communication program.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Aug 26, 2022
- Abate by
- Sep 22, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
2260
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. (a) Columbiana Boiler Company, LLC, on or about March 24th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: Multiple secondary containers were used by employees for more than a single day and outside of their individual control without the benefit of having appropriate labeling in place.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1910.132 D02
- Issued
- Aug 26, 2022
- Abate by
- Sep 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): (a) Columbiana Boiler Company, LLC, on or about March 24th, 2022, at the location of 200 W. RAILROAD ST., COLUMBIANA, OH 44408: Employees utilized personal protective equipment including, gloves and safety glasses, to change propane tanks, but the employer did not verify the hazard assessment for this activity through a written certification.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Columbiana Boiler Company, LLC
View Columbiana Boiler Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345854152.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.