Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G.S. SUPERIOR CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G.S. SUPERIOR CONSTRUCTION, INC. in 2000 RIDGE, HIGHLAND PARK, IL 60035 (NAICS 238160). OSHA activity number 345864045.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G.S. Superior Construction, INC. — free Get an email when a new federal OSHA severe-injury report for G.S. Superior Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2000 RIDGE
City
HIGHLAND PARK
State
IL
ZIP
60035
Mailing
635 EDGEMONT LANE, PARK RIDGE, IL 60068
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.451 G01 III

Serious Gravity 10 6 instances 6 exposed
Issued
Jun 8, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board:     a) On or about March 28, 2022, employees were exposed to the hazard of falling from a pitched roof while on a crawling board (chicken ladder) located on the roof deck.      No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $4351

1926.452 M01

Serious Gravity 10 2 instances 6 exposed
Issued
Jun 8, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.452(m)(1): Crawling boards did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance:     a) On or about March 28, 2022, ladders used as crawling boards (chicken ladders) did not extend from the roof peak to the eave when used during roofing work.     No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

1926.452 M02

Serious Gravity 10 2 instances 6 exposed
Issued
Jun 8, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.452(m)(2): Crawling boards were not secured to the roof by ridge hooks or by means that meet equivalent criteria (e.g., strength and durability):     a) On or about March 28, 2022, ladders used as crawling boards (chicken ladders) were not secured to the roof by ridge hooks or by other means.    No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 6 instances 6 exposed
Issued
Jun 8, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):        a) On or about March 28, 2022, employees were exposed to the hazard of falling while working from the roof of a residential structure without fall protection.        No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 8, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:       a) On or about March 28, 2022, employees were exposed to the hazard of falling where a portable extension ladder did not extend at least 3 feet above the landing surface of the roof deck.         No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $3108

1926.1053 B09

Serious Gravity 5 2 instances 6 exposed
Issued
Jun 8, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR 1926.1053(b)(9):The area around the top and bottom of ladders was not kept clear:  a) On or about March 28 2022, employees were exposed to fall hazards where roof tear-off material was accumulated at the top and bottom of a portable extension ladder used to climb to and from the roof deck.    No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $3108

View G.S. Superior Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345864045.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.