MOUNT HOPE, OH —
OSHA Inspection: OVERHEAD DOOR CORPORATION - WAYNE DALTON
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OVERHEAD DOOR CORPORATION - WAYNE DALTON in 4405 COUNTY ROAD 160, MOUNT HOPE, OH 44660 (NAICS 321911). OSHA activity number 345864177.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OVERHEAD DOOR CORPORATION - WAYNE DALTON
- Site address
- 4405 COUNTY ROAD 160
- City
- MOUNT HOPE
- State
- OH
- ZIP
- 44660
- Mailing
- 4405 COUNTY ROAD 160, MOUNT HOPE, OH 44660
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 450
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II A
- Issued
- Jun 1, 2022
- Abate by
- Jun 13, 2022
- Penalty
- Initial $11,396 · Current $11,396
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(A): A specific statement of the intended use of the procedure; a. On or about February 26, 2022, located at 4405 County Road 160 in Mount Hope, Ohio, the employer did not ensure the specific procedures for ID# Furnace #8 (version supplied to CSHO in document request) had a specific statement of the intended use of procedures, exposing employees to caught in hazards. b. On or about February 26, 2022, located at 4405 County Road 160 in Mount Hope, Ohio, the employer did not ensure the specific procedures for "ID# Dip Tank & Conv" (version kept at dip tank conveyor) had a specific statement of the intended use of procedures, exposing employees to caught in hazards.
Recent events (2)
- — I (S) $11396
- — Z (S) $11396
1910.147 C04 II B
- Issued
- Jun 1, 2022
- Abate by
- Jun 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(B):Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a. On or about February 26, 2022, located at 4405 County Road 160 in Mount Hope, Ohio, the employer did not ensure the specific procedures for ID# Furnace #8 (version supplied to CSHO in document request) had specific procedural steps for addressing all energy sources, exposing employees to thermal burn hazards. b. On or about February 26, 2022, located at 4405 County Road 160 in Mount Hope, Ohio, the employer did not ensure the specific procedures for "ID# Dip Tank & Conv" (version kept at dip tank conveyor) had specific procedural steps for addressing all energy sources, exposing employees to thermal burn hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- Jun 1, 2022
- Abate by
- Jun 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(D):Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a. On or about February 26, 2022, located at 4405 County Road 160 in Mount Hope, Ohio, the employer did not ensure the specific procedures for ID# Furnace #8 (version supplied to CSHO in document request) had a specific requirement for testing the equipment to verify the effectiveness of the lockout device, exposing employees to caught in and thermal burn hazards. b. On or about February 26, 2022, located at 4405 County Road 160 in Mount Hope, Ohio, the employer did not ensure the specific procedures for "ID# Dip Tank & Conv" (version kept at dip tank conveyor) had a specific requirement for testing the equipment to verify the effectiveness of the lockout device, exposing employees to caught in and thermal burn hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F04
- Issued
- Jun 1, 2022
- Abate by
- Jun 13, 2022
- Penalty
- Initial $11,396 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(f)(4):Shift or personnel changes. Specific procedures shall be utilized during shift or personnel changes to ensure the continuity of lockout or tagout protection, including provision for the orderly transfer of lockout or tagout device protection between off-going and oncoming employees, to minimize exposure to hazards from the unexpected energization or start-up of the machine or equipment, or the release of stored energy. a. On or about February 26, 2022, located at 4405 County Road 160 in Mount Hope, Ohio, the employer did not ensure the specific procedures were utilized when transferring locks on the dip tank line in the spring department, exposing employees to caught in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $11396
More inspections at Overhead Door Corporation - Wayne Dalton
View Overhead Door Corporation - Wayne Dalton's full OSHA safety record →
More inspections in this industry (NAICS 321911)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345864177.