Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BELMONT SOLAR, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BELMONT SOLAR, LLC in 3376 HARVEST DRIVE, GORDONVILLE, PA 17529 (NAICS 238210). OSHA activity number 345879845.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Belmont Solar, LLC — free Get an email when a new federal OSHA severe-injury report for Belmont Solar, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BELMONT SOLAR, LLC
Site address
3376 HARVEST DRIVE
City
GORDONVILLE
State
PA
ZIP
17529
Mailing
3376 HARVEST DRIVE, GORDONVILLE, PA 17529
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.502 D06 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2022
Abate by
Jul 26, 2022
Penalty
Initial $3,108 · Current $0 Reduced
29 CFR  1926.502(d)(6)(i): Snap hooks were connected directly to webbing, rope or wire rope:  a) Roof - Employees utilized vertical lifelines whose snap hooks were connected directly to the webbing while performing solar panel installation approximately 20 feet high above ground, on or about April 6, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3108

1926.502 D15 II

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 29, 2022
Abate by
Jul 26, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest systems were not designed, installed and used under the supervision of a qualified person:   a) Roof - Employees anchored their personal fall arrest system to the rails of a solar panel rack system that was not designed, installed and used under the supervision of a qualified person, on or about April 6, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D17

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jun 29, 2022
Abate by
Jul 26, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:  a) Roof - Employees donned a full body harness as part of a personal fall arrest system with the lanyard attached at their waist, on or about April 6, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 29, 2022
Abate by
Aug 31, 2022
Penalty
Initial $0 · Current $1,200
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee who was exposed to fall hazards that enabled each employee to recognize the hazards of falling and train each employee in the procedures to be followed in order to minimize these hazards.   a) Roof - Employees were not trained in appropriate fall protection methods to avoid hazards associated with elevated work areas, on or about, on or about April 6, 2022.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $0

1926.1053 B01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jun 29, 2022
Penalty
Initial $3,108 · Current $0 Reduced
29 CFR  1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a) Job Site - Employees used a 24 ft. Werner portable extension ladder to access the roof and the side rails extended approximately 1 foot above the landing surface. The ladder was secured at its top but no grasping device was provided to assist employees in mounting and dismounting the ladder, thereby exposing employees to an approximate 20 foot fall hazard to the ground below, on or about April 6, 2022.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3108

1926.1060 A01 III

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 29, 2022
Abate by
Aug 31, 2022
Penalty
Initial $0 · Current $1,200
29 CFR  1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways:  a) Job Site - Employees were not trained by a competent person in the proper use and placement of portable extension ladders,  on or about April 6, 2022.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $0

View Belmont Solar, LLC's full OSHA safety record →