OSHA Inspection: MARINE CORPS AIR STATION MIRAMAR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARINE CORPS AIR STATION MIRAMAR in BUILDING B6200 PASS & ID - VISITOR CENTER, SAN DIEGO, CA 92145 (NAICS 928110). OSHA activity number 345894703.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marine Corps AIR Station Miramar — free Get an email when a new federal OSHA severe-injury report for Marine Corps AIR Station Miramar is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING B6200 PASS & ID - VISITOR CENTER
City
SAN DIEGO
State
CA
ZIP
92145
Mailing
9320 MIRAMAR WAY, SAN DIEGO, CA 92145
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
4
Ownership type
D

7 citations on file for this inspection.

1910.157 E02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   Building B6200:  Employee(s) occupy the building in the performance of their assigned tasks. The fire extinguisher inside the workspace had not been subjected to an monthly functionality maintenance check.  This condition potentially exposes employee(s) to fire and/or emergency evacuation hazard(s).
Recent events (1)
  • — Z (S) $0

1910.157 E03

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3):The date of the annual maintenance check of portable fire extinguishers was not recorded:  Building B6200:  Employee(s) occupy the building in the performance of their assigned tasks. The fire extinguisher inside the workspace had not been subjected to an annual functionality maintenance check.  This condition potentially exposes employee(s) to fire and/or emergency evacuation hazard(s).
Recent events (1)
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Building B6200:  The employer permitted materials to be stored directly in front of the electrical panel(s). This condition interferes with access and immediate shutdown of a circuit in the panel, particularly in the event of an emergency. Employee(s) were exposed to the potential of shock and/or fire hazard(s).
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   Building B6200: Electronic equipment, computer laptops, radios, a phone, and small appliances such as coffee maker were plugged into relocatable power taps which were daisy chained and not used according to listing and labeling instructions. Employee(s) were exposed to potential electrical shock and/or fire hazard(s).
Recent events (1)
  • — Z (S) $0

1910.1200 F10

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(10):  The employer did not ensure that workplace labels or other forms of warnings were prominently displayed on the container or readily available in the work area throughout each work shift  Building B6200:  Employees used unlabeled secondary containers to hold chemicals such as SEM Lube Oil used during the paper shredding process.  The employer did not ensure containers had prominently displayed labels showing chemical name, associated hazards, and warnings.  The employees were exposed to dermal burns.
Recent events (1)
  • — Z (S) $0

1910.1200 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  Building B6200:  Employees used chemicals such as SEM Lube Oil during the paper shredding process.  The employer did not ensure a safety data sheet was located onsite and available to employees.  The employees were exposed to dermal burns.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Building B6200:  Employees used chemicals such as SEM Lube Oil during the paper shredding process.  The employer did not ensure effective information and training on hazardous chemicals in their work area when a new hazard was introduced.  The employees were exposed to dermal burns.
Recent events (1)
  • — Z (S) $0

View Marine Corps AIR Station Miramar's full OSHA safety record →