Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PCC AIRFOILS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PCC AIRFOILS LLC in 3860 UNION AVE. SE, MINERVA, OH 44657 (NAICS 423860). OSHA activity number 345904585.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PCC Airfoils LLC — free Get an email when a new federal OSHA severe-injury report for PCC Airfoils LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PCC AIRFOILS LLC
Site address
3860 UNION AVE. SE
City
MINERVA
State
OH
ZIP
44657
Mailing
3860 UNION AVE. SE, MINERVA, OH 44657
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423860
Employees
436
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 16, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.147(c)(4)(i):Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about April 7, 2022 at 3860 Union Avenue SE, Minerva OH 44657  in the MCL Prep Lab, the employer failed to ensure employees troubleshooting locked out the pneumatics in that an employee accidently cycled the hold down vice while there finger was inside the vice.
Recent events (1)
  • — Z (S) $14502

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 16, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about April 7, 2022 at 3860 Union Avenue SE, Minerva OH 44657  in the MCL Prep Lab,  employees were exposed to machine hazards associated with moving parts and crushing hazards while troubleshooting the 20TCO Cut-off saw. The employer failed to ensure the implement energy control application steps were followed as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation, dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
  • — Z (S) $0

View PCC Airfoils LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345904585.