Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LOCKHEED MARTIN CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LOCKHEED MARTIN CORPORATION in 498 OAK ROAD, OCALA, FL 34472 (NAICS 336414). OSHA activity number 345908362.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lockheed Martin Corporation — free Get an email when a new federal OSHA severe-injury report for Lockheed Martin Corporation is published. One employer, no account, unsubscribe in one click.
Site address
498 OAK ROAD
City
OCALA
State
FL
ZIP
34472
Mailing
6801 ROCKLEDGE DR, BETHESDA, MD 20817
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336414
Employees
251
Ownership type
A

3 citations on file for this inspection.

1910.132 A

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
May 23, 2022
Abate by
Jun 17, 2022
Penalty
Initial $12,431 · Current $0 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:   a. On or about April 14, 2022, at the facility, employees were performing inspections on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not wearing electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards.  b. On or about April 14, 2022, at the facility, employees were performing testing on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not wearing electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12431

1910.335 A01 I

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
May 23, 2022
Abate by
Jun 17, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:   a. On or about April 14, 2022, at the facility, employees were performing inspections on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not were not provided electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards.  b. On or about April 14, 2022, at the facility, employees were performing testing on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not were not provided electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 A

Other-than-serious Gravity 5 2 instances 1 exposed
Issued
May 23, 2022
Abate by
Jun 17, 2022
Penalty
Initial $12,431 · Current $0 Reduced
29 CFR  1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:  a. On or about April 14, 2022, at the facility, employees were performing inspections on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employer had not established and employed safety related work practices, that which prevent electric shock or other injuries resulting from either direct or indirect electrical contact; therefore exposing the employee to electric shock and thermal burn hazards.  b. On or about April 14, 2022, at the facility, employees were performing testing on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employer had not established and employed safety related work practices, that which prevent electric shock or other injuries resulting from either direct or indirect electrical contact; therefore exposing the employee to electric shock and thermal burn hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $12431

View Lockheed Martin Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345908362.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.