OCALA, FL —
OSHA Inspection: LOCKHEED MARTIN CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LOCKHEED MARTIN CORPORATION in 498 OAK ROAD, OCALA, FL 34472 (NAICS 336414). OSHA activity number 345908362.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LOCKHEED MARTIN CORPORATION
- Site address
- 498 OAK ROAD
- City
- OCALA
- State
- FL
- ZIP
- 34472
- Mailing
- 6801 ROCKLEDGE DR, BETHESDA, MD 20817
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336414
- Employees
- 251
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.132 A
- Issued
- May 23, 2022
- Abate by
- Jun 17, 2022
- Penalty
- Initial $12,431 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a. On or about April 14, 2022, at the facility, employees were performing inspections on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not wearing electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards. b. On or about April 14, 2022, at the facility, employees were performing testing on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not wearing electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $12431
1910.335 A01 I
- Issued
- May 23, 2022
- Abate by
- Jun 17, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a. On or about April 14, 2022, at the facility, employees were performing inspections on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not were not provided electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards. b. On or about April 14, 2022, at the facility, employees were performing testing on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employees were not were not provided electrically insulated gloves; therefore, exposing the employee to electric shock and thermal burn hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 A
- Issued
- May 23, 2022
- Abate by
- Jun 17, 2022
- Penalty
- Initial $12,431 · Current $0 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: a. On or about April 14, 2022, at the facility, employees were performing inspections on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employer had not established and employed safety related work practices, that which prevent electric shock or other injuries resulting from either direct or indirect electrical contact; therefore exposing the employee to electric shock and thermal burn hazards. b. On or about April 14, 2022, at the facility, employees were performing testing on EMI filters, a sub-assembly component of an aircraft missile and fire control system, that which contained stored electrical energy of 208 Volts AC, during which time the employer had not established and employed safety related work practices, that which prevent electric shock or other injuries resulting from either direct or indirect electrical contact; therefore exposing the employee to electric shock and thermal burn hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $12431
More inspections at Lockheed Martin Corporation
View Lockheed Martin Corporation's full OSHA safety record →
More inspections in this industry (NAICS 336414)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345908362.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.