COLUMBIA, MO —
OSHA Inspection: AURORA ORGANIC DAIRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AURORA ORGANIC DAIRY in 4525 WACO ROAD, COLUMBIA, MO 65202 (NAICS 112120). OSHA activity number 345928998.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AURORA ORGANIC DAIRY
- Site address
- 4525 WACO ROAD
- City
- COLUMBIA
- State
- MO
- ZIP
- 65202
- Mailing
- 4525 WACO ROAD, COLUMBIA, MO 65202
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 112120
- Employees
- 120
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.119 D03 I B
- Issued
- Oct 14, 2022
- Abate by
- Nov 9, 2022
- Penalty
- Initial $14,502 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): The employer did not include all equipment that was part of the process on piping and instrument diagrams. At the worksite located at 4525 Waco Road, Columbia, Missouri: Employees were exposed to hazards related to highly hazardous chemicals onsite. The employer did not ensure the Process Safety Information depicted on the Piping and Instrument Diagram was up-to-date and accurate. A)[6] Project Gatway PID Set For Record-PID.04 did not accurately depict the installed instruments in that Flow Control Valve EC1A.08 was not identified in the field. B) [6] Project Gatway PID Set For Record-PID.04 did not accurately depict the installed instruments in that Gate Valve EC1C.02 was not identified in the field. C) [6] Project Gatway PID Set For Record-PID.04 did not accurately depict the installed instruments in that Flow Control Valve EC1C.08 was not identified in the field.
Recent events (2)
- — I (S) $0
- — Z (S) $14502
More inspections at Aurora Organic Dairy
View Aurora Organic Dairy's full OSHA safety record →
More inspections in this industry (NAICS 112120)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345928998.