Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELITE BROTHERS CONSTRUCTION LLC

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of ELITE BROTHERS CONSTRUCTION LLC in 361 - 367 MARSHALL ST, PATERSON, NJ 07503 (NAICS 238140). OSHA activity number 345944227.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elite Brothers Construction LLC — free Get an email when a new federal OSHA severe-injury report for Elite Brothers Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
361 - 367 MARSHALL ST
City
PATERSON
State
NJ
ZIP
07503
Mailing
432 E 24TH STREET, PATERSON, NJ 07514
Inspection type
Special Programs (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.451 C01 II

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 13, 2022
Penalty
Initial $4,786 · Current $4,786
29 CFR  1926.451(c)(1)(ii): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by installing guys, ties, and braces according to the manufacturer's recommendation.   a)  At or near 361 -367 Marshall St., Paterson NJ - Frame Scaffold - Right façade perpendicular to Marshall St.: employees worked from a 5 tier high fabricated frame scaffold which was not tied, guyed or braced  while engaged in masonry activities, on or about 5/3/22 through 6/7/22.
Recent events (1)
  • — Z (S) $4786

1926.451 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 13, 2022
Penalty
Initial $4,786 · Current $4,786
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:  a)  At or near 361 -367 Marshall St., Paterson NJ - Frame Scaffold - Right façade perpendicular to Marshall St.: employees worked from a 5 tier high fabricated frame scaffold erected without base plates on dirt  while engaged in masonry activities, on or about 5/3/22 through 6/7/22.
Recent events (1)
  • — Z (S) $4786

1926.451 C02 II

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 13, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units.   a)  At or near 361 -367 Marshall St., Paterson NJ - Frame Scaffold - Right façade perpendicular to Marshall St.: employees worked from a 5 tier frame high scaffold erected on hollow concrete blocks while performing masonry activities, on or about 5/3/22 through 6/7/22.
Recent events (1)
  • — Z (S) $0

1926.416 A01

Willful Gravity 10 6 instances 2 exposed
Issued
Oct 13, 2022
Abate by
Oct 24, 2022
Penalty
Initial $31,906 · Current $31,906
29 CFR  1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a)  At or near 361 -367 Marshall St., Paterson NJ - Articulated Boom - Left facade perpendicular to Marshall St: employees were exposed to electric hazards while installing base stuco finish utilizing  an articulated boom lift on a multi-story residential building  approximately 7 feet from a 13KV/26KV/69KV  primary lines, on or about 4/16/22 through 5/3/22.  b)  At or near 361 -367 Marshall St., Paterson NJ - Articulated Boom - Right facade perpendicular to Marshall St.: employees were exposed to electric hazards while installing base and finish stuco finish utilizing  an articulated boom lift on a multi-story residential building  approximately 7 feet from a 13KV/26KV/69KV  primary lines, on or about 4/16/22 through 5/3/22.  c)  At or near 361 -367 Marshall St., Paterson NJ - Articulated Boom - Left facade perpendicular to Marshall St.: employees were exposed to electric hazards while installing final stuco finish utilizing  an articulated boom lift on a multi-story residential building  approximately 7 feet from a 13KV/26KV/69KV  primary lines, on or about 5/3/22 through 6/722.
Recent events (1)
  • — Z (W) $31906

View Elite Brothers Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345944227.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.