HERMON, ME —
OSHA Inspection: INSTALLED BUILDING PRODUCTS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of INSTALLED BUILDING PRODUCTS in 10 PRINTERS DRIVE SUITE 14, HERMON, ME 04401 (NAICS 238310). OSHA activity number 345951917.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INSTALLED BUILDING PRODUCTS
- Site address
- 10 PRINTERS DRIVE SUITE 14
- City
- HERMON
- State
- ME
- ZIP
- 04401
- Mailing
- 10 PRINTERS DRIVE SUITE 14, HERMON, ME 04401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 26
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.55 A01
- Issued
- Jul 14, 2022
- Abate by
- Oct 13, 2022
- Penalty
- Initial $8,629 · Current $4,315 Reduced
1073
General-duty citation text
29 CFR 1926.55(a)(1): Employee(s) were exposed to material(s) with a permissible exposure limit preceded by (C) at a concentration above that specified in Table 1 of �1926.55 for that material, as determined from breathing-zone air samples: Shore Cottage Road, Southwest Harbor, Maine - Employees were exposed to methylene bisphenyl isocyanate at amounts greater than the PEL Ceiling of 0.2 milligrams per cubic meter.
Recent events (2)
- — I (S) $4314.5
- — Z (S) $8629
1926.1203 A
- Issued
- Jul 14, 2022
- Abate by
- Oct 13, 2022
- Penalty
- Initial $8,629 · Current $4,315 Reduced
1073
General-duty citation text
29 CFR 1926.1203(a): Before it began work at a worksite, the employer did not ensure that a competent person identified all confined spaces in which one or more of the employees it directed may have worked, and/or did not identify each space that was a permit space, through consideration and evaluation of the elements of that space, including testing as necessary: Shore Cottage Road, Southwest Harbor, Maine - An evaluation of the work area by a competent person did not include testing and other considerations that identify confined spaces, as permit required.
Recent events (2)
- — I (S) $4314.5
- — Z (S) $8629
1910.303 G01
- Issued
- Jul 14, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Warehouse Bay Doors and Front Office Entrance - A trash can blocked the electrical panel and was located within the taped off boundary.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Installed Building Products
View Installed Building Products's full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345951917.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.