WARREN, OH —
OSHA Inspection: ULTIUM CELLS LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ULTIUM CELLS LLC in 7400 TOD AVENUE SOUTHWEST, WARREN, OH 44481 (NAICS 335912). OSHA activity number 345961221.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ULTIUM CELLS LLC
- Site address
- 7400 TOD AVENUE SOUTHWEST
- City
- WARREN
- State
- OH
- ZIP
- 44481
- Mailing
- 7400 TOD AVENUE SOUTHWEST, WARREN, OH 44481
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335912
- Employees
- 450
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.38 C01
- Issued
- Nov 7, 2022
- Abate by
- Jan 31, 2023
- Penalty
- Initial $10,360 · Current $6,216 Reduced
General-duty citation text
29 CFR 1910.38(c)(1):The employer did not implement an emergency evacuation plan which included at a minimum the elements required by paragraphs 1910.38(c)(1)-(6) of this part. On or about May 17, 2022, the employer did not include the procedures for reporting a fire within their emergency action plan.
Recent events (2)
- — I (O) $6216
- — Z (S) $10360
1910.38 C02
- Issued
- Nov 7, 2022
- Abate by
- Jan 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(c)(2): 29CFR 1910.38(c)(2): The written program did not include procedures for emergency evacuation, including type of evacuation and exit route assignments; On or about May 17, 2022, the employer did not include the procedures for emergency evacuation, including the type of evacuation and exit route assignments, within their emergency action plan.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.38 C04
- Issued
- Nov 7, 2022
- Abate by
- Jan 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(c)(4): 20 CFR 1910.38(c)(4): The emergency action plan, at a minimum, did not include procedure for accountability for all employees after evacuation. On or about May 17, 2022, the employer did not include the procedures for accountability for all employees after evacuation within their written emergency action plan.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.38 C06
- Issued
- Nov 7, 2022
- Abate by
- Jan 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(c)(6): 29 CFR 1910.38(c)(6): The emergency action plan did not include the name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan. On or about May 17, 2022, the employer did not include the name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan within their emergency action plan.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.39 B
- Issued
- Nov 7, 2022
- Abate by
- Dec 27, 2022
- Penalty
- Initial $6,215 · Current $0 Reduced
General-duty citation text
29 CFR 1910.39(b): A fire prevention was not in writing, kept in the workplace, and made available to employees for review: On or about May 17, 2022, a fire prevention plan was not in writing and/or kept in the workplace and/or made available to employees as required.
Recent events (2)
- — I (S) $0
- — Z (S) $6215
1910.147 C04 II
- Issued
- Nov 7, 2022
- Abate by
- Dec 27, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section: a.) On or about May 17, 2022, the employers energy control procedure did not contain a specific statement of intended use or specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them for the Anode Mixing-Coater Top 1 Machine. b.) On or about May 17, 2022, the employers energy control procedure did not contain a specific statement of intended use or specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them for the Anode Mixing- AC 1 Machine.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ultium Cells LLC
View Ultium Cells LLC's full OSHA safety record →
More inspections in this industry (NAICS 335912)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345961221.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.