Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ULTIUM CELLS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ULTIUM CELLS LLC in 7400 TOD AVENUE SOUTHWEST, WARREN, OH 44481 (NAICS 335912). OSHA activity number 345961221.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ultium Cells LLC — free Get an email when a new federal OSHA severe-injury report for Ultium Cells LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ULTIUM CELLS LLC
Site address
7400 TOD AVENUE SOUTHWEST
City
WARREN
State
OH
ZIP
44481
Mailing
7400 TOD AVENUE SOUTHWEST, WARREN, OH 44481
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335912
Employees
450
Ownership type
A

6 citations on file for this inspection.

1910.38 C01

Other-than-serious Gravity 5 1 instance 9 exposed
Issued
Nov 7, 2022
Abate by
Jan 31, 2023
Penalty
Initial $10,360 · Current $6,216 Reduced
29 CFR  1910.38(c)(1):The employer did not implement an emergency evacuation plan which included at a minimum the elements required by paragraphs 1910.38(c)(1)-(6) of this part.  On or about May 17, 2022, the employer did not include the procedures for reporting a fire within their emergency action plan.
Recent events (2)
  • — I (O) $6216
  • — Z (S) $10360

1910.38 C02

Other-than-serious Gravity 5 1 instance 9 exposed
Issued
Nov 7, 2022
Abate by
Jan 31, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.38(c)(2): 29CFR 1910.38(c)(2): The written program did not include procedures for emergency evacuation, including type of evacuation and exit route assignments;  On or about May 17, 2022, the employer did not include the procedures for emergency evacuation, including the type of evacuation and exit route assignments, within their emergency action plan.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.38 C04

Other-than-serious Gravity 5 1 instance 9 exposed
Issued
Nov 7, 2022
Abate by
Jan 31, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.38(c)(4): 20 CFR 1910.38(c)(4): The emergency action plan, at a minimum, did not include procedure for accountability for all employees after evacuation.    On or about May 17, 2022, the employer did not include the procedures for accountability for all employees after evacuation within their written emergency action plan.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.38 C06

Other-than-serious Gravity 5 1 instance 9 exposed
Issued
Nov 7, 2022
Abate by
Jan 31, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.38(c)(6): 29 CFR 1910.38(c)(6):  The emergency action plan did not include the name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan.  On or about May 17, 2022, the employer did not include the name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan within their emergency action plan.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.39 B

Deleted Serious Gravity 1 1 instance 9 exposed
Issued
Nov 7, 2022
Abate by
Dec 27, 2022
Penalty
Initial $6,215 · Current $0 Reduced
29 CFR  1910.39(b): A fire prevention was not in writing, kept in the workplace, and made available to employees for review:  On or about May 17, 2022, a fire prevention plan was not in writing and/or kept in the workplace and/or made available to employees as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6215

1910.147 C04 II

Deleted Other-than-serious 1 instance 2 exposed
Issued
Nov 7, 2022
Abate by
Dec 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section:   a.) On or about May 17, 2022, the employers energy control procedure did not contain a specific statement of intended use or specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them for the Anode Mixing-Coater Top 1 Machine.   b.) On or about May 17, 2022, the employers energy control procedure did not contain a specific statement of intended use or specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them for the Anode Mixing- AC 1 Machine.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Ultium Cells LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345961221.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.