GONZALES, LA —
OSHA Inspection: CARBON SIX BARRELS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CARBON SIX BARRELS, LLC in 10093 RAYCO SANDRES RD, GONZALES, LA 70737 (NAICS 332999). OSHA activity number 345967038.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARBON SIX BARRELS, LLC
- Site address
- 10093 RAYCO SANDRES RD
- City
- GONZALES
- State
- LA
- ZIP
- 70737
- Mailing
- 10093 RAYCO SANDRES RD, GONZALES, LA 70737
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 10
- Ownership type
- A
Citations
20 citations on file for this inspection.
1910.133 A01
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $3,729 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.133(a)(1):The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about May 18, 2022, inside the carbon barrel sanding booth, employees were required to operate a sanding lathe to sand carbon fiber barrels without the use of eye protection.
Recent events (2)
- — I (S) $2500
- — Z (S) $3729
1910.134 C01
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) On or about May 18, 2022, inside the carbon barrel sanding booth, employees were required to wear half-face tight-fitting elastomeric respirators while sanding carbon fiber barrels without first implementing a respiratory protection program.
Recent events (2)
- — I (S) $1865
- — Z (S) $1865
1910.134 E01
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about May 18, 2022, inside the carbon barrel sanding booth, employees were required to wear half-face tight-fitting elastomeric respirators while sanding carbon fiber barrels without a medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F05
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(5): The fit test was not administered using an OSHA-accepted qualitative fit test or quantitative fit test protocol: a) On or about May 18, 2022, inside the carbon barrel sanding booth, employees were required to wear half-face tight-fitting elastomeric respirators while sanding carbon fiber barrels without first conducting an OSHA-accepted qualitative or quantitative fit test.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $2,486 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) On or about May 18, 2022, inside the carbon barrel sanding booth, an employee with facial hair was observed wearing a half-face tight-fitting elastomeric respirator while sanding carbon fiber barrels
Recent events (2)
- — I (S) $1700
- — Z (S) $2486
1910.134 H01 II
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $3,729 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.134(h)(1)(ii): Respirators issued to more than one employee were not cleaned and disinfected before being worn by different individuals: a) On or about May 18, 2022, near the carbon fiber sanding booth, employees were exposed to contaminants from respirators that were used by more than one employee and were not sanitized and cleaned prior to each use.
Recent events (2)
- — I (S) $1500
- — Z (S) $3729
1910.134 H02 I
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $3,108 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.134(h)(2)(i):All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve. a) On or about May 18, 2022 outside the carbon barrel sanding booth, employees stored t half-faced tight-fitting respirators in places that did not prevent potential damage to the respirator. Two half-face tight-fitting elastomeric respirators were stored on a wire shelf exposing them to the elements and dust produced in the area.
Recent events (2)
- — I (S) $1500
- — Z (S) $3108
1910.134 K01
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $2,486 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training that covered the required elements in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii): a) On or about May 18, 2022, employees wore tight-fitting respirators for sanding without first receiving training and information.
Recent events (2)
- — I (S) $1700
- — Z (S) $2486
1910.157 E01
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $2,486 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.157(e)(1):The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace: a) On or about May 18, 2022, throughout the shop portable fire extinguishers required for incipient level fires were not serviced for more than one year.
Recent events (2)
- — I (S) $1000
- — Z (S) $2486
1910.212 A01
- Issued
- Nov 8, 2022
- Penalty
- Initial $4,351 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about May 18, 2022, in the shop, employees utilized a Grizzly G4003G Lathe without a chuck guard.
Recent events (2)
- — I (S) $3000
- — Z (S) $4351
1910.213 C01
- Issued
- Nov 8, 2022
- Penalty
- Initial $2,642 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) On or about May 18, 2022, in the front shop area, employees utilized a DeWalt Power Saw model DWE7491 S#(201434-ct027198) without a hood guard.
Recent events (2)
- — I (S) $0
- — Z (S) $2642
1910.213 C03
- Issued
- Nov 8, 2022
- Abate by
- Nov 29, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3):Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On or about May 18, 2022, in the front shop area, employees utilized a DeWalt Power Saw model DWE7491 S#(201434-ct027198) with having non kickback fingers installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $4,351 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about May 18, 2022, at the back side of the shop next to CNC machine with carbon filter, employees utilized relocatable power taps that were connected in series (daisy chained) to power shop equipment: a) Near the carbon filter CNC machine, employees connected and utilized daisy chains to connect power pools. b) Near the back workbench, employees connected and utilized daisy chains to connect power tools and charging stations. c) Near the front workbench, employees connected and utilized daisy chains to connect a table saw, power tools, and charging stations.
Recent events (2)
- — I (S) $1500
- — Z (S) $4351
1910.303 B07 I
- Issued
- Nov 8, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. a) On or about May 18, 2022 in the Shop where carbon dust accumulated, the employer failed to ensure a Circuit Breaker panel was closed to prevent electric shock, deflagration, or other fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1910.303 C03 I
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $4,351 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. On or about May 18, 2022, the employer did not ensure that spliced and repaired wiring contained equivalent insulation: a) Inside the carbon fiber sanding booth where carbon dust accumulated, the sanding lathe motor wires were spliced and repaired without proper insulation. b) Near the wooden workbench at the front of the shop where wood dust accumulated, electrical wires to a ballast light system were spliced and repaired without proper insulation.
Recent events (2)
- — I (S) $1000
- — Z (S) $4351
1910.303 G02 I
- Issued
- Nov 8, 2022
- Abate by
- Nov 29, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about May 18, 2022, employees worked where live parts of electrical equipment were not guarded against direct or indirect contact. a) Inside the carbon fiber sanding booth, the sanding lathe motor wires were not covered or enclosed in an approved enclosure. b) Near the wooden workbench at the front of the shop, electrical wires to a ballast light system were not covered or enclosed in an approved enclosure.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1910.305 B02 I
- Issued
- Nov 8, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about May 18, 2022, employees worked near live electrical outlets with missing faceplates. a) Behind the sander, the employees utilized 110v wall electrical outlets that did not have protective face plates installed. b) Near the sanding booth, the employees utilized 110v wall electrical outlets that did not have protective face plates installed. c) Near the carbon dust collector unit, the power box containing the power leads to the motor did not have its factory-provided faceplate installed.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1910.1200 E01
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $3,729 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: a)On or about May 18, 2022 throughout the facility employees were exposed to hazardous substances including but not limited to Carbon Dust (combustible), Fused Aluminum Oxide, and Trim Sol without the employer having a written HAZCOM Program.
Recent events (2)
- — I (S) $2500
- — Z (S) $3729
1910.1200 H02 III
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $3,729 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(2)(iii):The employer did not provide information to the employees as to the location and availability of the written hazard communication program, and material safety data sheets required by 29 CFR 1910.1200: a) On or about May 18, 2022 throughout the facility employees who worked with hazardous substances including but not limited to Carbon Dust (x), Fused Aluminum Oxide, and Trim Sol were not provided access to information with the Safety Data Sheets.
Recent events (2)
- — I (S) $0
- — Z (S) $3729
1904.40 A
- Issued
- Nov 8, 2022
- Abate by
- Jan 5, 2023
- Penalty
- Initial $622 · Current $622
General-duty citation text
29 CFR 1904.40(a):The employer did not provide an authorized government representative the records within the four business hours. a) On or about May 18, 2022, at the facility located at 10093 Rayco Sandres Rd. Gonzales, LA 70737 the employer did not provide OSHA Form 300 logs for calendar years 2019, 2020, and 2021 to an authorized government representative within four business hours.
Recent events (2)
- — I (O) $622
- — Z (O) $622
More inspections at Carbon SIX Barrels, LLC
View Carbon SIX Barrels, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345967038.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.