HONOLULU, HI —
OSHA Inspection: HALE KOA ARMED FORCES RECREATION CENTER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HALE KOA ARMED FORCES RECREATION CENTER in 2055 KALIA ROAD, HONOLULU, HI 96815 (NAICS 721110). OSHA activity number 345971980.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALE KOA ARMED FORCES RECREATION CENTER
- Site address
- 2055 KALIA ROAD
- City
- HONOLULU
- State
- HI
- ZIP
- 96815
- Mailing
- 2055 KALIA ROAD, HONOLULU, HI 96815
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 621
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.22 A02
- Issued
- May 27, 2022
- Abate by
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided. Main kitchen dish washing area: The floor in the dish washing area had standing water and no mats for employees to stand and walk on. Employees were exposed to slip and fall hazards.
Recent events (1)
- — Z (S) $0
1910.23 B08
- Issued
- May 27, 2022
- Abate by
- Jun 9, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(b)(8): The employer did not ensure that ladders are used only for the purposes for which they were designed. Hot water boiler room: A ladder was used in the vertical position to support a wood plank for elevating employees five feet to paint overhead pipes. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $0
1910.28 B05 I
- Issued
- May 27, 2022
- Abate by
- Jun 9, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(5)(i): The employer did not ensure that each employee on a runway or similar walkway is protected from falling 4 feet (1.2 m) or more to a lower level by a guardrail system. Hot water boiler room: A twelve foot long nine inch wide platform was elevated over five feet for painting pipes with no guard rails. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $0
1910.134 E01
- Issued
- May 27, 2022
- Abate by
- Jun 24, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Landscaping department: At least three employees were required to wear N95 respirators while using the skid steer rotary broom and were not fit tested annually. Employees were exposed to respiratory hazards.
Recent events (1)
- — Z (S) $0
1910.134 F02
- Issued
- May 27, 2022
- Abate by
- Jun 24, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a. Landscaping department: At least three employees were required to wear N95 respirators while using the skid steer rotary broom were not fit tested annually. Employees were exposed to respiratory hazards. b. Paint shop: At least three employees were required to wear half-face respirators while conducting painting activities were not fit tested annually. Employees were exposed to respiratory hazards.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- May 27, 2022
- Abate by
- Jun 24, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Receiving warehouse: A knockout was missing from the top right of the 460 volt electrical switch providing power to the Hy-Press cardboard compacter. Employees were exposed to electrical hazards.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- May 27, 2022
- Abate by
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Warehouse: An extension cord was secured to the wall and draped over ducts to supply power to lights above the refrigerator. Employees were exposed to fire and electrical hazards. b. Happy's Pool Bar: Extension cords were zip tied to conduit and the frame of a pop-up tent to supply power to lights, a cash register, a fan, and a relocatable power tap. Employees were exposed to fire and electrical hazards.
Recent events (1)
- — Z (S) $0
1910.1030 F02 I
- Issued
- May 27, 2022
- Abate by
- Jul 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(f)(2)(i): Hepatitis B vaccination was not made available within 10 working days of initial assignment to all employee(s) with occupational exposure: Hale Koa Hotel: All lifeguard and first responder employees who have occupational exposure to bloodborne pathogens were not offered the Hepatitis B vaccine within 10 days of initial assignment. Employees were exposed to biological hazards.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- May 27, 2022
- Abate by
- Jun 9, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. Housekeeping warehouse: A relocatable power tap was mounted to the wall to provide power to an overhead fan. Employees were exposed to fire and electrical hazards. b. Outside of the housekeeping warehouse: A relocatable power tap was zip tied to conduit providing power to the housekeeping time clock. Employees were exposed to fire and electrical hazards. c. Outside of the warehouse: A relocatable power tap was zip tied to conduit providing power to the maintenance and warehouse time clock. Employees were exposed to fire and electrical hazards.
Recent events (1)
- — Z (O) $0
More inspections at Hale KOA Armed Forces Recreation Center
View Hale KOA Armed Forces Recreation Center's full OSHA safety record →
More inspections in this industry (NAICS 721110)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345971980.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.