Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORLE BUILDING SYSTEMS

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of CORLE BUILDING SYSTEMS in 404 SARAH FURNACE ROAD, IMLER, PA 16655 (NAICS 332311). OSHA activity number 345992192.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corle Building Systems — free Get an email when a new federal OSHA severe-injury report for Corle Building Systems is published. One employer, no account, unsubscribe in one click.
Site address
404 SARAH FURNACE ROAD
City
IMLER
State
PA
ZIP
16655
Mailing
404 SARAH FURNACE ROAD, IMLER, PA 16655
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
250
Ownership type
A

4 citations on file for this inspection.

1910.134 E01

Repeat 1 instance 1 exposed
Issued
Aug 4, 2022
Abate by
Sep 21, 2022
Penalty
Initial $410 · Current $410
29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a)  In the Facility, on or about June 1, 2022 - The employer did not provide a medical evaluation to determine the employee's ability to use a respirator in the workplace before the employee was required to use a respirator in the workplace.  Employees of the facility are required to use a half mask tight fitting respirator during painting operations.   Corle Building Systems was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.134 (e)(1), which was contained in OSHA inspection number 1384498, citation number 1, item number 2a, and was affirmed as a final order on May 20, 2019, with respect to a workplace located at 404 Sarah Furnace Road, Imler, PA.
Recent events (1)
  • — Z (R) $410

1910.134 F02

Repeat 1 instance 2 exposed
Issued
Aug 4, 2022
Abate by
Sep 21, 2022
Penalty
Initial $410 · Current $410
29 CFR  1910.134(f)(2):  The employer did not ensure that an employee using a tight-fitting respirator is fit tested prior to initial use, whenever a different respirator facepiece (size, style, make or model) is used, and at least annually thereafter:   a)  In the Facility, on or about June 1, 2022 - The employer did not ensure that an employee using a tight-fitting respirator was fit-tested prior to the use of that respirator.  Employees of the facility are required to use a half mask tight fitting respirator during painting operations.  b)  In the Facility, on or about June 1, 2022 - The employer did not ensure that an employee using a tight-fitting respirator was fit-tested whenever a different respirator facepiece was used.  Employees of the facility are required to use a half mask tight fitting respirator during painting operations.   Corle Building Systems was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.134(f)(2), which was contained in OSHA inspection number 1384498, citation number 1, item number 2b, and was affirmed as a final order on May 20, 2019, with respect to a workplace located at 404 Sarah Furnace Road, Imler, PA.
Recent events (1)
  • — Z (R) $410

1910.134 K03

Repeat 1 instance 1 exposed
Issued
Aug 4, 2022
Abate by
Sep 21, 2022
Penalty
Initial $410 · Current $410
29 CFR  1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a)  In the Facility, on or about June 1, 2022 - The employer did not provide respirator training to employees prior to requiring the use of a respirator in the workplace.    Employees of the facility are required to use a half mask tight fitting respirator during painting operations.   Corle Building Systems was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.134(k)(3) was contained in OSHA inspection number 1384498, citation number 1, item number 2c, and was affirmed as a final order on May 20, 2019, with respect to a workplace located at 404 Sarah Furnace Road, Imler, PA.
Recent events (1)
  • — Z (R) $410

1910.134 M02 I C

Other-than-serious 1 instance 1 exposed
Issued
Aug 4, 2022
Abate by
Sep 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(m)(2)(i)(C): The employer did not establish a record of the qualitative and quantitative fit tests administered to an employee which included the specific make, model, style and size of respirator tested:   a)  In the Facility, on or about June 1, 2022 - The employer's record of the qualitative fit tests administered to employees did not include the specific make, model, style and size of respirator tested.
Recent events (1)
  • — Z (O) $0

View Corle Building Systems's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345992192.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.