OSHA Inspection: J&A AEROSPACE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of J&A AEROSPACE, INC. in 202 DAY ST, WEST SPRINGFIELD, MA 01089 (NAICS 423310). OSHA activity number 346023336.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J&A Aerospace, INC. — free Get an email when a new federal OSHA severe-injury report for J&A Aerospace, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
J&A AEROSPACE, INC.
Site address
202 DAY ST
City
WEST SPRINGFIELD
State
MA
ZIP
01089
Mailing
202 DAY ST, WEST SPRINGFIELD, MA 01089
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423310
Employees
29
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 12, 2022
Abate by
Sep 29, 2022
Penalty
Initial $7,252 · Current $3,626 Reduced
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   202 Day St, West Springfield, MA:  On June 16, 2022 and at times prior, the employer had not established an energy control program to protect employees and outside contractors who performed set up, cleaning, unjamming, maintenance, and servicing activities on machinery.  Abatement Notes*:  Energy control procedures are required to be: - Documented for all multiple-energy source machines including the Chambon sliding table saw. - Followed by employees and outside contractors   Energy Control training is to be documented and is required for all employees who are, or may be, in an area where energy control procedures may be utilized.  A periodic inspection is to include the following elements:  - Appointment of an authorized employee to inspect each energy control procedure for inaccuracies during an actual energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections  *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act.
Recent events (2)
  • — I (S) $3626
  • — Z (S) $7252

1910.213 B03

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 12, 2022
Abate by
Sep 29, 2022
Penalty
Initial $7,252 · Current $3,626 Reduced
29 CFR  1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after a power failure. 202 Day Street, West Springfield, MA 01089:  On June 16, 2022 and at times prior,  employees were exposed to laceration and amputation hazards when they operated a Chambon sliding table saw that did not have a provision to prevent it from automatically restarting upon restoration of power after a power interruption.
Recent events (2)
  • — I (S) $3626
  • — Z (S) $7252

View J&A Aerospace, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346023336.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.