OSHA Inspection: NPL CONSTRUCTION COMPANY, MID-AMERICA OFFICE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NPL CONSTRUCTION COMPANY, MID-AMERICA OFFICE in JOHNSON AND FOSTER DRIVE., SHAWNEE, KS 66203 (NAICS 237120). OSHA activity number 346041106.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NPL Construction Company, Mid-America Office — free Get an email when a new federal OSHA severe-injury report for NPL Construction Company, Mid-America Office is published. One employer, no account, unsubscribe in one click.
Site address
JOHNSON AND FOSTER DRIVE.
City
SHAWNEE
State
KS
ZIP
66203
Mailing
1120 NORTHWEST HIGHWAY 24, TOPEKA, KS 66618
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.403 G

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Oct 13, 2022
Abate by
Nov 8, 2022
Penalty
Initial $8,287 · Current $8,287
29 CFR  1926.403(g):Electrical equipment which was used did not have other markings giving voltage, current, wattage, or other ratings as necessary:  Employees working at Johnson and Foster Dr., Shawnee, Kansas 66203 engaged in trenching activities  were exposed to electrical hazards in that a home-made outlet device which did not have markings giving voltage, wattage, or other ratings was used to power tools on-site. The device was powered by an extension cord.
Recent events (2)
  • — I (O) $8287
  • — Z (S) $8287

1926.405 G02 IV

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Oct 13, 2022
Abate by
Nov 8, 2022
Penalty
Initial $6,215 · Current $6,215
29 CFR  1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  Employees working at Johnson and Foster Dr., Shawnee, Kansas 66203 engaged in trenching activities were exposed to electrical hazards in that the extension cords used to supply power to the home-made outlet device was not equipped with adequate strain relief.  As a result the extension cord showed signs of damage.  The insulation had pulled away from the plug, exposing the conductors.
Recent events (2)
  • — I (O) $6215
  • — Z (S) $6215

1926.652 A01

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Oct 13, 2022
Abate by
Nov 8, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  Employees working at Johnson and Foster Dr. Shawnee, Kansas 66203 engaged in gas line repair activities, inside of an excavation found to be approximately 7 feet in depth, were exposed to cave-in hazards in that adequate cave-in protective system was not provided.
Recent events (2)
  • — I (O) $14502
  • — Z (S) $14502

View NPL Construction Company, Mid-America Office's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346041106.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.