Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUSTER PRODUCTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LUSTER PRODUCTS, INC. in 1104 W. 43RD STREET, CHICAGO, IL 60609 (NAICS 326299). OSHA activity number 346041924.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luster Products, INC. — free Get an email when a new federal OSHA severe-injury report for Luster Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1104 W. 43RD STREET
City
CHICAGO
State
IL
ZIP
60609
Mailing
1104 W. 43RD STREET, CHICAGO, IL 60609
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
138
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 3, 2022
Abate by
Nov 16, 2022
Penalty
Initial $13,052 · Current $13,052
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  a) Production Department - On or about June 16, 2022, the employer failed to provide training to each authorized employee performing service and/or maintenance to the Resina Capper machine to ensure the employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices.
Recent events (1)
  • — Z (S) $13052

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 3, 2022
Abate by
Nov 16, 2022
Penalty
Initial $13,052 · Current $13,052
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   a) Production Department - On or about June 16, 2022, employees were exposed to machine hazards associated with moving parts when cleaning and removing jams from the Resina Capper Machine. The employer failed to implement energy control application steps as the machine was not shut down or turn off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.
Recent events (1)
  • — Z (S) $13052

View Luster Products, INC.'s full OSHA safety record →