Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RANGER ENERGY SERVICES, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of RANGER ENERGY SERVICES, LLC in WILSON CREEK UNIT 69, RIG #5545 2500 COUNTY ROAD 9, MEEKER, CO 81641 (NAICS 213112). OSHA activity number 346060379.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ranger Energy Services, LLC — free Get an email when a new federal OSHA severe-injury report for Ranger Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
WILSON CREEK UNIT 69, RIG #5545 2500 COUNTY ROAD 9
City
MEEKER
State
CO
ZIP
81641
Mailing
10350 RICHMOND AVE. SUITE 550, HOUSTON, TX 77042
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 23, 2022
Abate by
Oct 29, 2024
Penalty
Initial $14,502 · Current $14,502
29 CFR 1910.22(a)(1): the employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition:  (a) Ranger Energy Services, LLC, Wilson Creek Unit 69, Rig #5545 2500 County Road 9 Meeker, CO 81641: On June 29, 2022, the employer did not ensure that the rig floor of Ranger Energy Services Rig #5545 was kept in a clean and sanitary condition when, during a stripping job, it did not take adequate measures to minimize the wellbore fluids being dispersed on the walking-working surfaces of the rig floor.
Recent events (3)
  • — F (S) $14502
  • — C (S) $14502
  • — Z (S) $14502

1910.252 A01 III

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 23, 2022
Abate by
Oct 29, 2024
Penalty
Initial $14,502 · Current $14,502
29 CFR 1910.252(a)(1)(iii): Welding or cutting was performed, when the requirements stated in 29 CFR 1910.252(a)(1)(i) and 29 CFR 1910.252(a)(1)(ii) could not be followed:  (a) Ranger Energy Services, LLC, Wilson Creek Unit 69, Rig #5545 2500 County Road 9 Meeker, CO 81641: On June 29, 2022, the employer allowed cutting to occur over an open well before the requirements of the standard were met.
Recent events (3)
  • — F (S) $14502
  • — C (S) $14502
  • — Z (S) $14502

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 23, 2022
Abate by
Oct 29, 2024
Penalty
Initial $145,027 · Current $145,027
OSH Act of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to respiratory, fire, and explosion hazards.  (a) Ranger Energy Services, LLC, Wilson Creek Unit 69, Rig #5545 2500 County Road 9 Meeker, CO 81641: On June 29, 2022, the employer did not ensure that employees wore personal air monitoring equipment when working on the rig floor where wet strings of tubing were being pulled from the well.
Recent events (3)
  • — F (S) $145027
  • — C (W) $145027
  • — Z (W) $145027

1910.307 C02 I

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 23, 2022
Abate by
Oct 29, 2024
Penalty
Initial $145,027 · Current $145,027
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the class of location:  (a) Ranger Energy Services, LLC, Wilson Creek Unit 69, Rig #5545 2500 County Road 9 Meeker, CO 81641: On June 29, 2022, the employer used an electrical bandsaw to cut a continuous rod over an open well that was not approved for the Class 1 Division 1 location it was operated in.
Recent events (3)
  • — F (S) $145027
  • — C (W) $145027
  • — Z (W) $145027