Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STURGEON ELECTRIC COMPANY, INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of STURGEON ELECTRIC COMPANY, INC. in 1244 SPEER BLVD, DENVER, CO 80204 (NAICS 238210). OSHA activity number 346092620.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sturgeon Electric Company, INC. — free Get an email when a new federal OSHA severe-injury report for Sturgeon Electric Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1244 SPEER BLVD
City
DENVER
State
CO
ZIP
80204
Mailing
12150 EAST 112TH AVENUE, HENDERSON, CO 80640
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
980
Ownership type
A

1 citation on file for this inspection.

1926.501 B04 I

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Dec 1, 2022
Penalty
Initial $7,485 · Current $0 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.  (a)	On or before July 21, 2022, the employer did not ensure employees were protected from falling through holes on the walking/working surface by utilizing an adequate protective system. Employees working within close proximity to the two caisson holes that ranged in depth from 8 feet to 18 feet with a diameter of 24 inches. This condition exposed employees to fall hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $7485
  • — Z (S) $7485

View Sturgeon Electric Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346092620.