BOISE, ID —
OSHA Inspection: KNIFE RIVER CORPORATION - MOUNTAIN WEST
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KNIFE RIVER CORPORATION - MOUNTAIN WEST in W DALCROSS DR., BOISE, ID 83714 (NAICS 238910). OSHA activity number 346093412.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KNIFE RIVER CORPORATION - MOUNTAIN WEST
- Site address
- W DALCROSS DR.
- City
- BOISE
- State
- ID
- ZIP
- 83714
- Mailing
- 5450 W. GOWEN ROAD, BOISE, ID 83709
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.651 J01
- Issued
- Jan 12, 2023
- Penalty
- Initial $14,502 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face: a) On July 20, 2022: Employees worked inside a 5.8 foot trench box (E0050371) which did not have end caps installed. Trench walls were within 1 foot of the exposed ends of trench box. Note* Abatement certification IS NOT required.
Recent events (2)
- — I (S) $0
- — Z (S) $14502
1926.652 C03 III
- Issued
- Jan 12, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(c)(3)(iii): At least one copy of the tabulated data, which identifies the registered professional engineer who approved the data, was not maintained at the jobsite during construction of the protective system. After that time the data may be stored off the jobsite, but a copy of the data shall be made available to the Secretary upon request. a) On July 20, 2022: Tabulated data was not provided to an OSHA representative upon request; two employees connecting pipe for new fire hydrants were working inside a 5.8 foot trench box (E0050371). NOTE: Abatement certification is not required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 K02
- Issued
- Jan 12, 2023
- Abate by
- Feb 8, 2023
- Penalty
- Initial $14,502 · Current $4,515 Reduced
General-duty citation text
29 CFR 1926.651(k)(2):Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. a) On July 20, 2022: two employees connecting pipe for new fire hydrants were initially working in a 5.8 foot trench without cave-in protection. After cave-in protection had been installed, employees were not provided a ladder, the trench box was not placed in a way to restrict lateral movement and end caps were not installed on the trench box. NOTE: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $4515
- — Z (S) $14502
1926.652 G01 II
- Issued
- Jan 12, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(g)(1)(ii): Shields were not installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads: a) On July 20, 2022: Employees worked inside a 5.8 foot trench box (E0050371) which was not adequately balanced. A heavy-duty pipe was placed between the trench box and the trench wall in an attempt to keep the box from moving. An employee was clearing dirt from inside the trench to connect pipe for new fire hydrants, and one employee was holding the pipe in position. Note* Abatement certification IS NOT required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 C02
- Issued
- Jan 12, 2023
- Abate by
- Feb 8, 2023
- Penalty
- Initial $113,960 · Current $85,470 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On July 20, 2022: Employees were clearing dirt and cutting pipe from inside a 5.8 foot trench without cave-in protection, to connect a pipe for new fire hydrants. An access ladder was not inside the trench while employees were working. Note* Abatement certification and documentation IS required. Knife River Corporation - Mountain West was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.652(a)(1), which was contained in OSHA inspection number 1523458, citation number 2, item number 1, and was affirmed as a final order on 10/25/21, with respect to a workplace located at Franklin and Cloverdale, Boise, ID 83703. Knife River Corporation - Northwest was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1242651, citation number 1, item number 1b and was affirmed as a final order on 8/24/2017, with respect to a workplace located at Cameron Street in Kellogg, ID.
Recent events (2)
- — I (R) $85470
- — Z (R) $113960
1926.652 A01
- Issued
- Jan 12, 2023
- Abate by
- Feb 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) On July 20, 2022: two employees connecting pipe for new fire hydrants were working in a 5.8 foot trench without cave-in protection. b) On July 20, 2022: Employees worked inside a 5.8 foot trench box (E0050371) which did not have end caps installed. Trench walls were within 1 foot of the exposed ends of trench box. Note* Abatement certification and documentation IS required. Knife River Corporation - Mountain West was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.652(a)(1), which was contained in OSHA inspection number 1523458, citation number 2, item number 2(b), and was affirmed as a final order on 10/25/21, with respect to a workplace located at Franklin and Cloverdale, Boise, ID 83703. Knife River Corporation, dba Knife River was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1358224, citation number 1, item number 1b and was affirmed as a final order on 4/4/2019, with respect to a workplace located on 3rd Avenue and Main Street in Lava Hot Springs, ID.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at Knife River Corporation - Mountain West
View Knife River Corporation - Mountain West's full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346093412.