TRENTON, OH —
OSHA Inspection: MAGNODE A SHAPE CORP. COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAGNODE A SHAPE CORP. COMPANY in 400 EAST STATE STREET, TRENTON, OH 45067 (NAICS 331318). OSHA activity number 346130677.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNODE A SHAPE CORP. COMPANY
- Site address
- 400 EAST STATE STREET
- City
- TRENTON
- State
- OH
- ZIP
- 45067
- Mailing
- 400 EAST STATE STREET, TRENTON, OH 45067
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331318
- Employees
- 181
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Oct 25, 2022
- Penalty
- Initial $14,502 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii):The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (A) A specific statement of the intended use of the procedure; (B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; (C) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; a) On or about 8/1/2022 the employer did not ensure that the machine specific lock out procedures for the Power Press AIDA 1500 #345(model # NCI-1500) contained specific procedural steps for the control of energy sources such as the nitrogen cylinders while employee performed servicing such as replacing a cracked die.
Recent events (2)
- — I (S) $0
- — Z (S) $14502
1910.147 D
- Issued
- Oct 25, 2022
- Penalty
- Initial $14,502 · Current $14,502
General-duty citation text
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (1) Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy. (2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. (3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (4)(i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. (4)(ii) Lockout devices, where used, shall be affixed in a manner to that will hold the energy isolating devices in a "safe" or "off" position. (5)(i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. (5)(ii) If there is a possibility of reaccumulation of stored energy to a hazardous level, verification of isolation shall be continued until the servicing or maintenance is completed, or until the possibility of such accumulation no longer exists. (6) Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished. a) On 8/01/22 the employer did not ensure that employee(s) performing such task as replacing a cracked die on the AIDA 1500 Power Press #345 (model # NCI-1500) secured the stored energy in the nitrogen cylinders prior to starting the servicing process.
Recent events (2)
- — I (O) $14502
- — Z (S) $14502
More inspections at Magnode a Shape Corp. Company
View Magnode a Shape Corp. Company's full OSHA safety record →
More inspections in this industry (NAICS 331318)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346130677.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.