Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: T & R MASONRY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of T & R MASONRY, LLC in 2002 W. SELTICE WAY, POST FALLS, ID 83854 (NAICS 238140). OSHA activity number 346134273.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T & R Masonry, LLC — free Get an email when a new federal OSHA severe-injury report for T & R Masonry, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
T & R MASONRY, LLC
Site address
2002 W. SELTICE WAY
City
POST FALLS
State
ID
ZIP
83854
Mailing
11937 DYNAMITE LN., KUNA, ID 83634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2023
Abate by
Jan 31, 2023
Penalty
Initial $4,972 · Current $4,972
29 CFR  1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.    a) 2002 W. Seltice Way - On or about August 8, 2022, employees performing masonry working from a tubular welded frame scaffold near an opening where the planking was not complete up to the top rail placed at a 45 degree angle, leaving a triangular shaped fall opening.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (3)
  • — A (S) $4972
  • — I (S) $2734.6
  • — Z (S) $4972

1926.451 G04

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2023
Abate by
Jan 31, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph.   a) 2002 W. Seltice Way - On or about August 8, 2022, employees performing masonry working from a tubular welded frame scaffold near an opening with an unprotected edge on the third-tier south side corner, with a top rail installed, and the mid-rail or equivalent not installed, exposing employees to fall hazards greater than ten feet.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E09 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2023
Abate by
Feb 1, 2023
Penalty
Initial $4,144 · Current $4,144
29 CFR 1926.451(e)(9)(iv):  Cross braces on tubular welded frame scaffolds were used as a means of access or egress.  a) 2002 W. Seltice Way - On or about August 8, 2022, the employer did not protect employees from injury in that masonry employees were observed climbing and utilizing cross bracing members of a three-tier tubular welded frame scaffold as a means of access and egress, exposing employees to fall hazards of greater than 10 feet.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (3)
  • — A (S) $4144
  • — I (S) $2279.2
  • — Z (S) $4144

1926.454 A

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2023
Abate by
Feb 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  a) 2002 W. Seltice Way - On or about August 8, 2022, the employer did not ensure that employees were provided training on hazards associated with recognizing hazards associated with tubular welded frame scaffolding used for masonry tasks, exposing employees to fall hazards of greater than 10 feet.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B10

Other-than-serious 1 instance 5 exposed
Issued
Jan 11, 2023
Abate by
Feb 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were intermixed such that the components fit together with force and the scaffold's structural integrity was not maintained by the user:  a) 2002 W. Seltice Way - On or about August 8, 2022, the employer utilized metal lacing wire to secure scaffold components in lieu of connecting pins. Scaffold components were intermixed with other types of scaffold components.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View T & R Masonry, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346134273.