Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PYROTECNICO FIREWORKS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PYROTECNICO FIREWORKS INC. in 700 COUNTY ROAD 1102, ASHLAND, OH 44805 (NAICS 423910). OSHA activity number 346136682.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pyrotecnico Fireworks INC. — free Get an email when a new federal OSHA severe-injury report for Pyrotecnico Fireworks INC. is published. One employer, no account, unsubscribe in one click.
Site address
700 COUNTY ROAD 1102
City
ASHLAND
State
OH
ZIP
44805
Mailing
299 WILSON ROAD, NEW CASTLE, PA 16101
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423910
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.132 A

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jan 10, 2023
Abate by
Feb 2, 2023
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.132(a):Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  a) Pyrotecnico Fireworks, Inc. at the display site located at 700 County Road 1102 Ashland, Ohio.  On or about August 6, 2022 the employer did not ensure employees engaged in setup operations of a fireworks display were wearing 100% cotton clothing to prevent static electricity buildup. Employees attaching friction and static sensitive electric igniters to quick fuses on firework shells were exposed to hazards associated with the premature detonation of the firework in that the employees did not wear personal protective equipment to prevent the accumulation and discharge of static electricity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

1910.132 D02

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 10, 2023
Abate by
Jun 30, 2023
Penalty
Initial $14,502 · Current $7,251 Reduced
29 CFR  1910.132(d)(2):The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  a) Pyrotecnico Fireworks, Inc. at the display site located at 700 County Road 1102 Ashland, Ohio.  On or about August 6, 2022, the required workplace hazard assessment did not include a written certification that identified the person certifying the workplace and evaluation and date of the hazard assessment. Employees attaching friction and static sensitive electric igniters to quick fuses on firework shells were exposed to hazards associated with the premature detonation of the firework in that the employees did not wear personal protective equipment to prevent the accumulation and discharge of static electricity.
Recent events (3)
  • — P (S) $7251
  • — I (S) $7251
  • — Z (S) $14502

1910.132 F01

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 10, 2023
Abate by
Jun 30, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.132(f)(1):The employer did not provide training to each employee who is required by this section to use personal protective equipment:  a)  Pyrotecnico Fireworks, Inc. at the display site located at 700 County Road 1102 Ashland, Ohio.  On or about August 6, 2022 the employer did not ensure employees were trained to know when and what personal protective equipment is necessary when setting up firework displays. Employees attaching friction and static sensitive electric igniters to quick fuses on firework shells were exposed to hazards associated with the premature detonation of the firework in that the employees were not aware that personal protective equipment to prevent the accumulation and discharge of static electricity, such as, but not limited to static dissipated clothing and conductive shoes, were required.
Recent events (3)
  • — P (S) $0
  • — I (S) $0
  • — Z (S) $0

View Pyrotecnico Fireworks INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346136682.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.