OSHA Inspection: WESTROCK CP, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WESTROCK CP, LLC in 1290 CAMPGROUND RD, LANCASTER, OH 43130 (NAICS 322211). OSHA activity number 346163850.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Westrock CP, LLC — free Get an email when a new federal OSHA severe-injury report for Westrock CP, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
WESTROCK CP, LLC
Site address
1290 CAMPGROUND RD
City
LANCASTER
State
OH
ZIP
43130
Mailing
1290 CAMPGROUND RD, LANCASTER, OH 43130
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
125
Ownership type
A

2 citations on file for this inspection.

1910.145 C03

Other-than-serious Gravity 5 1 instance 13 exposed
Issued
Dec 14, 2022
Abate by
Apr 11, 2023
Penalty
Initial $11,396 · Current $7,500 Reduced
29 CFR 1910.145(c)(3):  Safety instruction signs. Safety instruction signs shall be used where there is a need for general instructions and suggestions relative to safety measures.   a. On or about August 15, 2022, employees were exposed to the moving parts of the Balmaster baler when lock out procedures were not utilized before troubleshooting the wire tying area of the baler.
Recent events (3)
  • — F (O) $7500
  • — C (S) $11396
  • — Z (S) $11396

1910.147 F01 II

Deleted Serious Gravity 5 1 instance 13 exposed
Issued
Dec 14, 2022
Abate by
Jan 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(1): Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed:   29 CFR  1910.147(f)(1)(ii): Remove employees from the machine or equipment area in accordance with paragraph (e)(2) of this section;   a. On or about August 15, 2022, the employer did not ensure that an employee's hand was protected from being caught-in the moving parts of the wire tying area while restarting the bailer machine to inspect and troubleshoot an issue affecting proper operation of the machine.