SPRINGFIELD, MA —
OSHA Inspection: WESTROCK CP, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WESTROCK CP, LLC in 320 PARKER ST, SPRINGFIELD, MA 01129 (NAICS 322211). OSHA activity number 346178320.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WESTROCK CP, LLC
- Site address
- 320 PARKER ST
- City
- SPRINGFIELD
- State
- MA
- ZIP
- 01129
- Mailing
- 320 PARKER ST, SPRINGFIELD, MA 01129
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 70000
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Nov 4, 2022
- Abate by
- Dec 23, 2022
- Penalty
- Initial $62,150 · Current $12,430 Reduced
General-duty citation text
1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. 320 Parker St, Springfield, MA: On August 29. 2022 and at times prior, employees performed maintenance and product unjamming on the mainline conveyor machine and the energy control procedure (LOTOP-050) for the mainline strapper machine did not include location of the electrical and pneumatic disconnects for the conveyor.
Recent events (2)
- — I (S) $12430
- — Z (R) $62150
1910.147 C06 II
- Issued
- Nov 4, 2022
- Abate by
- Dec 23, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii):The employer did not certify that the periodic inspections have been performed by identifying the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. 320 Parker St, Springfield, MA: On August 29. 2022 and for more than one year prior, the employer had no documentation to show that every energy control procedure had been inspected during an actual maintenance or servicing task.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Westrock CP, LLC
View Westrock CP, LLC's full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346178320.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.