Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THUNDERBOLT ROOFING & CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THUNDERBOLT ROOFING & CONSTRUCTION INC. in 175 E. OLIVE ST., ELMHURST, IL 60126 (NAICS 238160). OSHA activity number 346210248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thunderbolt Roofing & Construction INC. — free Get an email when a new federal OSHA severe-injury report for Thunderbolt Roofing & Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
175 E. OLIVE ST.
City
ELMHURST
State
IL
ZIP
60126
Mailing
277 BIRCH LANE, SAINT CHARLES, IL 60175
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2022
Abate by
Dec 8, 2022
Penalty
Initial $2,486 · Current $1,740 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.    On or about September 7, 2022, at jobsite located in 175 W. Olive St., Elmhurst, IL. 60126. Employees engaged in residential roofing operations were exposed to struck-by hazards while operating pneumatic nail guns without eye protection.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1740.2
  • — Z (S) $2486

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 18, 2022
Penalty
Initial $4,786 · Current $3,350 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system:  On or about September 7, 2022, at jobsite located in 175 W. Olive St., Elmhurst, IL. 60126, employees were exposed to fall hazards in excess of 18 feet while engaged in residential roofing activities. Fall protection was not being utilized adequately while performing roofing activities. Employees were wearing harness and not tied-off to a lifeline lanyard.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $3350.2
  • — Z (S) $4786

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 18, 2022
Abate by
Dec 12, 2022
Penalty
Initial $3,108 · Current $2,176 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On or about September 7, 2022, at jobsite located in 175 W. Olive St., Elmhurst, IL. 60126,  the portable ladder used to access the roof level did not extend at least three (3') feet above the upper landing surface, thereby exposing employees to fall hazard.   Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $2175.6
  • — Z (S) $3108

View Thunderbolt Roofing & Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346210248.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.