Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ERGON-WEST VIRGINIA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ERGON-WEST VIRGINIA, INC. in 9995 OHIO RIVER BLVD., NEWELL, WV 26050 (NAICS 324110). OSHA activity number 346229685.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ergon-West Virginia, INC. — free Get an email when a new federal OSHA severe-injury report for Ergon-West Virginia, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9995 OHIO RIVER BLVD.
City
NEWELL
State
WV
ZIP
26050
Mailing
P.O. BOX 356, NEWELL, WV 26050
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
Employees
200
Ownership type
A

1 citation on file for this inspection.

1910.147 D06

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2023
Abate by
Mar 30, 2023
Penalty
Initial $10,046 · Current $10,046
29 CFR 1910.147(d)(6):  Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  (a)  Hydrogen Gas Plant Unit (HGP2):  On September 6, 2022, employees were attempting to install blinds at the pressure swing adsorption vessel outlets in preparation of changing out a pressure relieve valve.  A verification was not conducted to ensure the pressure swing adsorption vessel was isolated resulting in the release of flammable hydrogen gas.
Recent events (1)
  • — Z (S) $10046

View Ergon-West Virginia, INC.'s full OSHA safety record →