Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BURRIS LOGISTICS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BURRIS LOGISTICS, INC. in 4501 DIGNAN ST., JACKSONVILLE, FL 32254 (NAICS 493120). OSHA activity number 346241631.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Burris Logistics, INC. — free Get an email when a new federal OSHA severe-injury report for Burris Logistics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4501 DIGNAN ST.
City
JACKSONVILLE
State
FL
ZIP
32254
Mailing
4501 DIGNAN ST., JACKSONVILLE, FL 32254
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
149
Ownership type
A

6 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 17, 2023
Penalty
Initial $5,692 · Current $4,269 Reduced
29 CFR  1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a.  At 4501 Dignan St, Jacksonville Florida:  On or about September 21, 2022, the employer exposed ammonia system operators to an egress obstruction hazard in the event of fire or ammonia release in that the ammonia engine room exit door did not have a panic bar release as required by ANSI/IIAR-2, Standard for Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems, paragraph 6.3.1.5.
Recent events (2)
  • — I (S) $4269
  • — Z (S) $5692

1910.119 D03 I B

Deleted Serious Gravity 5 1 instance 50 exposed
Issued
Mar 17, 2023
Penalty
Initial $7,590 · Current $0 Reduced
29 CFR  1910.119(d)(3)(i)(B):  The employer's piping and instrument diagrams (P&ID) were not accurate and did not represent equipment that was existing and was part of the process.  a.  At 4501 Dignan St, Jacksonville, Florida:  On or about September 21, 2022, the ammonia system piping and instrumentation diagrams (P&ID) were not accurate in that they did not note the decommissioning of the blast freezer piping, valve groups, air handling units, and evaporators that were removed from service in 2015 and were no longer part of the process.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7590

1910.119 E05

Serious Gravity 5 1 instance 50 exposed
Issued
Mar 17, 2023
Penalty
Initial $7,590 · Current $5,693 Reduced
29 CFR  1910.119(e)(5): The employer did not assure that Process Hazard Analysis (PHA) recommendations were resolved in a timely manner.  a.   At 4501 Dignan St, Jacksonville, Florida:  On or about September 21, 2022, the employer had not resolved 14 Process Hazard Analysis safety recommendation items from the September 30, 2022 Ammonia System Process Hazard Analysis, including items not assigned for action.
Recent events (2)
  • — I (S) $5692.5
  • — Z (S) $7590

1910.119 L04

Deleted Serious Gravity 1 1 instance 50 exposed
Issued
Mar 17, 2023
Penalty
Initial $5,692 · Current $0 Reduced
29 CFR  1910.119(l)(4): The employer did not update Process Safety Information (PSI) as required for Management of Change Statements (MOCS):  a.   At 4501 Dignan St, Jacksonville Florida:  On or about September 21, 2022, the employer had not updated the Process Safety Information Block Flow Diagrams and System Descriptions to reflect the 2021 Management of Change Statement for the removal of Blast Cell Walls and decommissioning of the  4 Blast Cell piping, evaporators, air handlers, and valve groups.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5692

1910.119 O04

Serious Gravity 5 1 instance 50 exposed
Issued
Mar 17, 2023
Penalty
Initial $7,590 · Current $5,693 Reduced
29 CFR  1910.119(o)(4):29 CFR 1910.119(o)(4):  The employer did not promptly respond to change recommendations from the Compliance Audit:  a.   At 4501 Dignan St, Jacksonville Florida:  On or about September 21, 2022, the employer had not resolved change recommendations and action items from the April 14, 2021 Ammonia System Process Safety Management Compliance Audit.
Recent events (2)
  • — I (S) $5692.5
  • — Z (S) $7590

1910.176 B

Serious Gravity 5 1 instance 20 exposed
Issued
Mar 17, 2023
Penalty
Initial $9,488 · Current $7,116 Reduced
29 CFR  1910.176(b):  Storage of material created a hazard:  a.   At 4501 Dignan St, Jacksonville Florida:  On or about September 21, 2022, in freezer storage room 5, powered industrial truck (PIT) operator employees were exposed to the hazard of being struck by pallets stored at heights up to 20-feet on the racking system shelves, in that pallets were unstable with boxed goods on pallets that had shifted and were leaning and protruding over the PIT travel aisles.
Recent events (2)
  • — I (S) $7116
  • — Z (S) $9488

View Burris Logistics, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346241631.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.