BAYTOWN, TX —
OSHA Inspection: EXXONMOBIL BAYTOWN REFINERY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EXXONMOBIL BAYTOWN REFINERY in 5000 BAYWAY DRIVE, BAYTOWN, TX 77520 (NAICS 324110). OSHA activity number 346251218.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EXXONMOBIL BAYTOWN REFINERY
- Site address
- 5000 BAYWAY DRIVE
- City
- BAYTOWN
- State
- TX
- ZIP
- 77520
- Mailing
- 5000 BAYWAY DRIVE, BAYTOWN, TX 77520
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324110
- Employees
- 1353
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 D03
- Issued
- Feb 23, 2023
- Abate by
- Apr 11, 2023
- Penalty
- Initial $15,625 · Current $15,625
General-duty citation text
1910.147(d)(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). On or about September 22, 2022, employees were exposed to chemical hazards when the low pressure side root valve for flow transmitter FNCLF615 to be used for isolation did not operate as intended to isolate the equipment from the energy source.
Recent events (3)
- — F (S) $15625
- — C (S) $15625
- — Z (S) $15625
1910.132 F03 III
- Issued
- Feb 23, 2023
- Abate by
- Apr 11, 2023
- Penalty
- Initial $15,625 · Current $15,625
General-duty citation text
29 CFR 1910.132(f)(3)(iii): When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (f)(2) of this section, the employer shall retrain each such employee. Circumstances where retraining is required include, but are not limited to, situations where: Inadequacies in an affected employee's knowledge or use of assigned PPE indicate that the employee has not retained the requisite understanding or skill. On or about September 22, 2022, the employer did not identify that personnel who were trained on PPE requirements, including selection and proper use, did not retain the knowledge to select and use PPE necessitated by the work activity being performed.
Recent events (3)
- — F (O) $15625
- — C (S) $15625
- — Z (S) $15625
1910.132 D01 I
- Issued
- Feb 23, 2023
- Abate by
- Apr 11, 2023
- Penalty
- Initial $15,625 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment; In the Alternative 29 CFR 1910.119(f)(4): The employer did not implement safe work practices to provide for the control of hazards during operations. These safe work practices shall apply to employees and contractor employees. On or about September 22, 2022, employees were exposed to chemical burns, fire, explosion and toxic gas release hazards when the employer did not ensure workers used the PPE identified in its procedure Removal of Instruments in Corrosive Service for the replacement of the flow transmitter CLF615 and its components.
Recent events (3)
- — F (S) $0
- — C (S) $15625
- — Z (S) $15625
1910.147 D05 II
- Issued
- Feb 23, 2023
- Abate by
- Apr 11, 2023
- Penalty
- Initial $15,625 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(5)(ii): If there is a possibility of reaccumulation of stored energy to a hazardous level, verification of isolation shall be continued until the servicing or maintenance is completed, or until the possibility of such accumulation no longer exists. On or about September 22, 2022, employees were exposed to chemical burns, fire, explosion and toxic gas release hazards when the employer did not ensure the energy isolation block valve on the low pressure side of the flow transmitter CLF615 continued to hold until the maintenance was completed.
Recent events (3)
- — F (S) $0
- — C (S) $15625
- — Z (S) $15625
1910.147 D03
- Issued
- Feb 23, 2023
- Abate by
- Apr 11, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that were needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). On or about September 22, 2022, employees were exposed to chemical burns, fire, explosion and toxic gas release hazards when the employer did not ensure the energy isolation block valve on the low pressure side of the flow transmitter CLF615 continued to hold until the maintenance was completed.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Exxonmobil Baytown Refinery
View Exxonmobil Baytown Refinery's full OSHA safety record →
More inspections in this industry (NAICS 324110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346251218.