Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NE STEEL FABRICATORS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NE STEEL FABRICATORS, LLC in 1655 ELMWOOD AVENUE SUITE 43, CRANSTON, RI 02910 (NAICS 238120). OSHA activity number 346252414.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NE Steel Fabricators, LLC — free Get an email when a new federal OSHA severe-injury report for NE Steel Fabricators, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1655 ELMWOOD AVENUE SUITE 43
City
CRANSTON
State
RI
ZIP
02910
Mailing
1120 WELLINGTON AVENUE P.O. BOX 6166, CRANSTON, RI 02910
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
4
Ownership type
A

9 citations on file for this inspection.

1903.19 C01

Other-than-serious 5 instances 4 exposed
Issued
Mar 9, 2023
Abate by
Apr 12, 2023
Penalty
Initial $965 · Current $965
29 CFR  1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  (a) Establishment:  As of March 8, 2023, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Items 1, 2, 3, 4, 5a, 5b and 5c from inspection number 1625241, issued on 12/8/2022, with a final order date of 2/1/2023.
Recent events (1)
  • — Z (O) $965

1903.19 D01

Other-than-serious 5 instances 4 exposed
Issued
Mar 9, 2023
Abate by
Apr 12, 2023
Penalty
Initial $0 · Current $0
29 CFR  1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  (a) Establishment:  As of March 8, 2023, the employer had not provided the required abatement documentation to OSHA for Citation 1, Items 1, 2, 3, 4, 5a, 5b and 5c from inspection number 1625241, issued on 12/8/2022 with a final order date 2/1/2023.
Recent events (1)
  • — Z (O) $0

1910.36 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 8, 2022
Abate by
Jan 4, 2023
Penalty
Initial $7,977 · Current $7,977
29 CFR  1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge.  (a) Worksite - East Side of Production Area - On or about 9/29/2022, an exit route door was locked with a slide-bolt from the interior preventing employees from rapid escape during an emergency.
Recent events (1)
  • — Z (S) $7977

1910.178 L01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 8, 2022
Abate by
Jan 26, 2023
Penalty
Initial $7,977 · Current $7,977
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a) Worksite - Production Area: On or about 9/29/2022, employees working in the production area are exposed to untrained Powered Industrial Truck operators.
Recent events (1)
  • — Z (S) $7977

1910.219 E03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 8, 2022
Abate by
Jan 26, 2023
Penalty
Initial $6,381 · Current $6,381
29 CFR  1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o).  (a) Worksite - Back Production Area: On or about 9/29/2022, employees were exposed to ingoing nip points at the pulley belt of the Forbes Picket Twisting machine.
Recent events (1)
  • — Z (S) $6381

1910.243 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 8, 2022
Abate by
Jan 26, 2023
Penalty
Initial $9,572 · Current $9,572
29 CFR  1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4).  (a) Worksite - Production Area: On or about 9/29/2022 an employee was exposed to flying chips and debris while using an unguarded handheld grinder.
Recent events (1)
  • — Z (S) $9572

1910.303 B08 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 8, 2022
Abate by
Jan 26, 2023
Penalty
Initial $6,381 · Current $6,381
29 CFR  1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted.  (a) Worksite - Production Area: On or about 9/29/2022 employees were exposed to electrical hazards while working near an electrical outlet that was not securely mounted.
Recent events (1)
  • — Z (S) $6381

1910.303 G02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 8, 2022
Abate by
Jan 26, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  (a) Worksite - Back Room Production Area: On or about 9/29/2022, employees were exposed to unguarded and stripped live electrical wires.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 8, 2022
Abate by
Jan 26, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose.  (a) Worksite - Back Production Area: On or about 9/29/2022, employees were exposed to live electrical wires when a junction box was not properly covered.
Recent events (1)
  • — Z (S) $0

View NE Steel Fabricators, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346252414.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.