NORTH SYRACUSE, NY —
OSHA Inspection: THE DECORATED COOKIE CO LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE DECORATED COOKIE CO LLC in 628 SOUTH MAIN STREET, NORTH SYRACUSE, NY 13212 (NAICS 311821). OSHA activity number 346265283.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE DECORATED COOKIE CO LLC
- Site address
- 628 SOUTH MAIN STREET
- City
- NORTH SYRACUSE
- State
- NY
- ZIP
- 13212
- Mailing
- 628 SOUTH MAIN STREET, NORTH SYRACUSE, NY 13212
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311821
- Employees
- 27
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Mar 17, 2023
- Abate by
- Mar 31, 2023
- Penalty
- Initial $10,938 · Current $7,657 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) At the establishment, on or about 10/6/2022 and times prior: The employer did not establish a lockout/tagout program with procedures, employee training and audits when employees are tasked to perform servicing activities on equipment including, but not limited to, the cookie line's conveyor, depositor and cutter, which have multiple energy sources, including electric and pneumatic.
Recent events (2)
- — I (S) $7656.6
- — Z (S) $10938
1910.157 B01
- Issued
- Mar 17, 2023
- Abate by
- Mar 31, 2023
- Penalty
- Initial $4,687 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(b)(1): A written emergency evacuation plan, meeting the requirements of 29 CFR 1910.38, was not developed and implemented where the employer elected to evacuate employees upon sounding of the a fire alarm: a) At 628 South Main Street, North Syracuse, NY, on or about 10/6/2022: An emergency action plan was not communicated to all its employees to ensure safe egress in case of an emergency.
Recent events (2)
- — I (S) $0
- — Z (S) $4687
More inspections at The Decorated Cookie CO LLC
View The Decorated Cookie CO LLC's full OSHA safety record →
More inspections in this industry (NAICS 311821)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346265283.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.