OSHA Inspection: BUREAU OF LAND MANAGEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUREAU OF LAND MANAGEMENT in 4700 BLM ROAD, ANCHORAGE, AK 99507 (NAICS 924120). OSHA activity number 346282312.

Watch Bureau OF Land Management — free Get an email when a new federal OSHA severe-injury report for Bureau OF Land Management is published. One employer, no account, unsubscribe in one click.
Site address
4700 BLM ROAD
City
ANCHORAGE
State
AK
ZIP
99507
Mailing
CAMPBELL TRACT FACILITY/4700 BLM ROAD, ANCHORAGE, AK 99507
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
100
Ownership type
D

10 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge.  a) Warm ATCO warehouse: On or about October 14, 2022 the emergency exit on the north wall of the facility was locked from the inside requiring special knowledge to exit the facility.
Recent events (1)
  • — Z (S) $0

1910.110 F02 I

Serious Gravity 5 1 instance 100 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.110(f)(2)(i): LP gas containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.  a) Outside Overhang: On or about October 14, 2022, four LP gas cylinders were not protected against physical damage. This condition exposes employees to a fire hazard.
Recent events (1)
  • — Z (S) $0

1910.110 B06 VII

Serious Gravity 5 1 instance 100 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.110(b)(6)(vii): The separation between liquefied petroleum gas containers and flammable liquid tanks was not 20 feet.    a) Outside overhand: On or about October 14, 2022, four LP gas cylinders were stored within approximately 5 feet of a flammable storage area exposing employees to a fire hazard.  b) Outside Overhang: On or about October 14, 2022, two propane tanks were stored with flammable gasoline exposing employees to a fire hazard.
Recent events (1)
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a) On or about October 14, 2022, a lockout tagout program was not established while  performing serving or maintenance on an American Hydraulic Scissor lift. This condition exposed employees to struck-by or amputation.  b) On or about October 14, 2022, a lockout tagout program was not established while  performing serving or maintenance on an AO Smith water heater. This condition exposed employees to electrical hazard or  fire hazard.  c) On or about October 14, 2022, a lockout tagout program was not established while  performing serving or maintenance on an American Webster Compressor. This condition exposed employees to electrical hazard.
Recent events (1)
  • — Z (S) $0

1910.179 J03

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.179(j)(3): A complete periodic inspection of crane had not been conducted in the past 12 months.  a) Maintenance Bay : On or about October 14, 2022, an overhead crane, P&H Model number 243N213 Serial number T32272 Unit 002, was not current on an annual periodic inspection. This condition exposed employees to an overhead struck-by hazard.
Recent events (1)
  • — Z (S) $0

1960.8 A

Serious Gravity 5 1 instance 100 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1960.8(a) : The Agency head did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm:  a) Warm ATCO Facility: On or about October 14, 2022, employees performed material handling operations using an industrial steal racking system for excess supplies on the shelving. Interior, front and rear column baseplates on the frames of the racking system were not anchored to the floor to resist all applicable forces, exposing employees to struck-by and crushing hazard.
Recent events (2)
  • — P (S) $0
  • — Z (S) $0

1904.33 A

Other-than-serious 1 instance 100 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1904.33(a):Employer did not retain the OSHA 300 log for each of the last 5 years.  a) On or about October 14, 2022 the employer did not retain the OSHA 300 logs for each of the last 5 years.
Recent events (1)
  • — Z (O) $0

1910.37 B06

Other-than-serious 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source.  Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted.  a) Carpentry Shop: On or about October 14, 2022 the exit sign for emergency exits did not meet the standard in that it was faded red sticker on the door.  b) Vehicle Maintenance Bay: On or about October 14, 2022 the exit sign for emergency exits  did not meet the standard in that it was faded red sticker on the door.  c) Equipment Maintenance Bay: On or about October 14, 2022 the exit sign for emergency exits  did not meet the standard in that it was spray painted red on the door.
Recent events (1)
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  a) Maintenance Bay: On or about October 14, 2022 a fire extinguisher was mounted on the back wall next to the exit door, was blocked by a mop bucket and mop exposing employees to fire hazards.
Recent events (1)
  • — Z (O) $0

1910.157 E03

Other-than-serious 4 instances 100 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(e)(3): The employer did not ensure that portable fire extinguishers were subjected to an annual maintenance check.  a) Warehouses: On or about October 14, 2022 fire extinguishers provided were not current on their annual inspection. This condition exposed employees to a fire and delayed egress hazard.  b) Maintenance Bays: On or about October 14, 2022 fire extinguishers provided were not current on their annual inspection. This condition exposed employees to a fire and delayed egress hazard.  c) Outside overhang: On or about October 14, 2022 fire extinguishers provided were not current on their annual inspection. This condition exposed employees to a fire and delayed egress hazard.  d) Carpentry Shop: On or about October 14, 2022 fire extinguishers provided were not current on their annual inspection. This condition exposed employees to a fire and delayed egress hazard.
Recent events (2)
  • — P (O) $0
  • — Z (O) $0