Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRIPLE J SAIPAN, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRIPLE J SAIPAN, INC. in SURFRIDER HOTEL BEACH ROAD, SAIPAN, MP 96950 (NAICS 721110). OSHA activity number 346295967.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Triple J Saipan, INC. — free Get an email when a new federal OSHA severe-injury report for Triple J Saipan, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SURFRIDER HOTEL BEACH ROAD
City
SAIPAN
State
MP
ZIP
96950
Mailing
PMB 103 P.O. BOX 1000 SAIPAN MP, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
15
Ownership type
A

7 citations on file for this inspection.

1910.147 A03 I

Other-than-serious Gravity 1 1 instance 50 exposed
Issued
Nov 30, 2022
Abate by
Dec 19, 2022
Penalty
Initial $5,283 · Current $2,642 Reduced
29 CFR  1910.147(a)(3)(i): The employer did not utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees.  Outside of the Hotel: Employees performed routine maintenance on multiple air conditioning units without utilizing appropriate lockout devices. Employees were exposed to electrical, caught-in, and rotating part hazards.
Recent events (3)
  • — F (O) $2641.5
  • — C (S) $5283
  • — Z (S) $5283

1910.303 B02

Other-than-serious 3 instances 4 exposed
Issued
Nov 30, 2022
Abate by
Dec 12, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. Maintenance office: The Project Architect's computer, phone, internet, and other electronics were  plugged into two series connected "daisy chained" relocatable power taps.  Employees were exposed to fire and electrical hazards.  b. Maintenance office: The Project Architect's computer, phone, internet, and other electronics were  supplied power from  a relocatable power tap that was screwed to the wall.  Employees were exposed to fire and electrical hazards.  c. Maintenance office: A Cannon C5235a Multi-Function printer was supplied power by an extension cord series connected "daisy chained" to a relocatable power tap. Employees were exposed to fire and electrical hazards.
Recent events (1)
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 15 exposed
Issued
Nov 30, 2022
Abate by
Dec 12, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Electrical Room: The main electrical panel for the  Surfrider Hotel was  blocked by various materials.  Access was restricted in the event of an emergency.
Recent events (1)
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2022
Abate by
Dec 19, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Outside of the south wing: A knockout was missing from the bottom right side of the electrical box providing power to the Gree Split Type Air Conditioner model GWC36LB-D3DNAG/O. Employees were exposed to electrical hazards.
Recent events (1)
  • — Z (O) $0

1910.305 C04

Other-than-serious 2 instances 8 exposed
Issued
Nov 30, 2022
Abate by
Dec 19, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface:  a. Electrical Room: The light switch controlling power to the overhead lights had a missing faceplate. Employees were exposed to electrical hazards.  b. IT Room: The light switch controlling power to the overhead lights had a missing faceplate. Employees were exposed to electrical hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 5 exposed
Issued
Nov 30, 2022
Abate by
Dec 19, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  Carpenter Shop: A list of all hazardous chemicals maintained within the carpenter shop was not developed. Employees were exposed to chemical hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 5 exposed
Issued
Nov 30, 2022
Abate by
Dec 19, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical  Carpenter Shop: The safety data sheets for Boysen Clear Gloss Lacquer, Ace Rust Stop, Varathane Wood Stain and various other chemicals in the Carpenter shop were not maintained. Employees were exposed to chemical hazards.
Recent events (1)
  • — Z (O) $0

View Triple J Saipan, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346295967.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.