MILL HALL, PA —
OSHA Inspection: CRODA, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of CRODA, INC. in 8 CRODA WAY, MILL HALL, PA 17751 (NAICS 325411). OSHA activity number 346303241.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRODA, INC.
- Site address
- 8 CRODA WAY
- City
- MILL HALL
- State
- PA
- ZIP
- 17751
- Mailing
- 8 CRODA WAY, MILL HALL, PA 17751
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325411
- Employees
- 175
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.119 F01 I B
- Issued
- Apr 17, 2023
- Abate by
- May 25, 2023
- Penalty
- Initial $6,261 · Current $6,261
11902215
General-duty citation text
29 CFR 1910.119(f)(1)(i)(B): The employer's written operating procedures did not address the steps for each operating phase of normal operations: a) Synthesis Area: The written operating procedure for the R-7 reaction vessel did not include steps to ensure adequate nitrogen pressure was maintained on the agitator seal, on or about October 25, 2022. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $6261
- — Z (S) $6261
1910.119 F01 II
- Issued
- Apr 17, 2023
- Abate by
- May 25, 2023
- Penalty
- Initial $0 · Current $0
11902215
General-duty citation text
29 CFR 1910.119(f)(1)(ii): The employer's written operating procedures did not address the requirements for the operating limits: a) Synthesis Area: The written operating procedure for the R-7 reaction vessel did not address the operating limits for the nitrogen pressure on the agitator seal, on or about October 25, 2022. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Croda, INC.
View Croda, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325411)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346303241.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.