Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARCHWAY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARCHWAY INC. in 147 SERENU AVE., TAMUNING, GU 96931 (NAICS 493110). OSHA activity number 346305360.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Archway INC. — free Get an email when a new federal OSHA severe-injury report for Archway INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ARCHWAY INC.
Site address
147 SERENU AVE.
City
TAMUNING
State
GU
ZIP
96931
Mailing
P.O. BOX 25867, BARRIGADA, GU 96921
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
40
Ownership type
A

7 citations on file for this inspection.

1910.36 B01

Serious Gravity 1 1 instance 13 exposed
Issued
Nov 8, 2022
Abate by
Dec 6, 2022
Penalty
Initial $5,594 · Current $3,916 Reduced
29 CFR  1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency.  Frontside Warehouse: Employees working within the frontside of the warehouse did not have an exit route within 50 feet of the dead end corridor as required by NFPA Table 40.2.5.1 . Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $3915.8
  • — Z (S) $5594

1910.213 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2022
Abate by
Nov 29, 2022
Penalty
Initial $9,324 · Current $6,527 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:   Carpenter Shop: A Ryobi Ten-inch table saw was operated with a missing automatically adjusting hood. Employees were exposed to amputation hazards.
Recent events (2)
  • — I (S) $6526.8
  • — Z (S) $9324

1910.305 G02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 8, 2022
Abate by
Nov 21, 2022
Penalty
Initial $9,324 · Current $6,527 Reduced
29 CFR  1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap:  Carpenter Shop: The flexible cable suppling power to a Maxx Air Pro fan had a splice and was not used in continuous length. Employees were exposed to fire and electrical hazards.
Recent events (2)
  • — I (S) $6526.8
  • — Z (S) $9324

1910.303 B02

Other-than-serious 1 instance 7 exposed
Issued
Nov 8, 2022
Abate by
Nov 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Warehouse: A relocatable power tap was secured to the wall providing power to three coffee grinders and a heating iron. Employees were exposed to fire and electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 2 instances 13 exposed
Issued
Nov 8, 2022
Abate by
Nov 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a. Carpenter Shop: An extension cord used to power various power tools was ran across the roof, draped over pipes in the roof structure. Employees were exposed to fire and electrical hazards.  b. Warehouse: An extension cord was used as a substitute for fixed wiring providing power to a fan on the warehouse mezzanine. Employees were exposed to fire and electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 4 exposed
Issued
Nov 8, 2022
Abate by
Nov 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  Kitchen: A list of all hazardous chemicals was not developed to include Ecolab Oasis 146 Multi-Quat Sanitizer and Ecolab Pantastic. Employees were exposed to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 4 exposed
Issued
Nov 8, 2022
Abate by
Nov 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:  Kitchen: The safety data sheet for Ecolab Oasis 146 Multi-Quat Sanitizer, Ecolab Pantastic, and other cleaning chemicals were not maintained. Employees were exposed to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0