TAMUNING, GU —
OSHA Inspection: CHANG CHIN, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHANG CHIN, INC. in 147B SIKET STREET, HARMON INDUSTRIAL PARK, TAMUNING, GU 96931 (NAICS 562219). OSHA activity number 346312507.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHANG CHIN, INC.
- Site address
- 147B SIKET STREET, HARMON INDUSTRIAL PARK
- City
- TAMUNING
- State
- GU
- ZIP
- 96931
- Mailing
- P.O. BOX 6075, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562219
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A03 II
- Issued
- Mar 9, 2023
- Abate by
- Mar 21, 2023
- Penalty
- Initial $2,679 · Current $2,679
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines, whose operation exposes an employee to injury, were not guarded. Receiving area: The blade guard was missing from the chop saw used to cut metal at the receiving area. Employees were exposed to laceration hazards.
Recent events (1)
- — Z (S) $2679
1910.305 B02 I
- Issued
- Mar 9, 2023
- Abate by
- Mar 21, 2023
- Penalty
- Initial $2,009 · Current $2,009
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: Fan, metal issue/receiving area: The fan motor back cover was missing exposing live electrical wiring. Employees were exposed to electrical hazards.
Recent events (1)
- — Z (S) $2009
1910.305 G02 II
- Issued
- Mar 9, 2023
- Abate by
- Mar 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap: Metal issuing section: The power cord for the fan used for ventilation was spliced exposing employees to electrical hazards.
Recent events (1)
- — Z (S) $0
1910.178 L04 III
- Issued
- Mar 9, 2023
- Abate by
- Apr 4, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: At least three employees operated forklifts without a performance evaluation in the previous three years. Employees were exposed to struck-by and crushed-by hazards.
Recent events (1)
- — Z (O) $0
1910.303 G01
- Issued
- Mar 9, 2023
- Abate by
- Mar 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a. Outside of the office: A refrigerator used to store employee lunches was placed in front of the panel used to power the office area hindering access in the event of an emergency. Employees were exposed to electrical hazards. b. Kitchen southwest corner: A pile of crates, dishes and groceries blocked access to the electrical panel used to power the kitchen hindering access in the event of an emergency. Employees were exposed to electrical hazards.
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Mar 9, 2023
- Abate by
- Mar 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Metal issuing area: The outer insulation to the power cable for the chop saw used to cut metals to size was pulled from the on/off switch box exposing employees to electrical hazards
Recent events (1)
- — Z (O) $0
More inspections at Chang Chin, INC.
View Chang Chin, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562219)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346312507.