Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. BORDER PATROL - TUCSON SECTOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. BORDER PATROL - TUCSON SECTOR in ATTEN: CHRISTOPHER KOEHLER 2430 S SWAN ROAD, TUCSON, AZ 85711 (NAICS 561210). OSHA activity number 346338825.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Border Patrol - Tucson Sector — free Get an email when a new federal OSHA severe-injury report for U.S. Border Patrol - Tucson Sector is published. One employer, no account, unsubscribe in one click.
Site address
ATTEN: CHRISTOPHER KOEHLER 2430 S SWAN ROAD
City
TUCSON
State
AZ
ZIP
85711
Mailing
ATTEN: SAFETY 2430 S SWAN ROAD, TUCSON, AZ 85711
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
350
Ownership type
D

9 citations on file for this inspection.

1910.22 B

Serious Gravity 10 3 instances 5 exposed
Issued
Jan 30, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.22(b):29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface. (a)	WAREHOUSE BREAK AREA- The break area located above the office exceeded the posted load rating of the mezzanine, exposing employees to injuries from the level collapsing.   (b)	WAREHOUSE- The load rating for the storage shelving above employee work areas had not been determined, exposing employees to injuries from the shelving collapsing.   (c)	BORTAC STORAGE- The load rating of the mezzanine had not been determined, exposing employees to injuries from the level collapsing.
Recent events (1)
  • — Z (S) $0

1910.37 A01

Serious Gravity 5 1 instance 20 exposed
Issued
Jan 30, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(1): The evacuation route contained hazardous and or flammable chemicals; or in the alternative 29 CFR  1910.106(d)(5)(i):Flammable liquids were stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.   (a)	GARAGE, ROOM 1020- The hallway leading to the emergency exit door was lined with flammable cabinets and flammable storage, exposing employees to burns.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 5 1 instance 20 exposed
Issued
Jan 30, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit":  (a)	GARAGE, ROOM 1020- The storage area did not have marked and visible emergency exit.
Recent events (1)
  • — Z (S) $0

1910.101 B

Serious Gravity 5 2 instances 6 exposed
Issued
Jan 30, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: (a)	WAREHOUSE MUNTIONS STORAGE:  Two cylinders of carbon dioxide were stored without being secured against tipping/falling, exposing employees to injuries from projectiles.  (b)	WAREHOUSE MUNITIONS STORAGE: A cylinder of carbon dioxide was stored with without a valve protection cap on, exposing employees to injuries from projectiles.
Recent events (1)
  • — Z (S) $0

1910.109 J02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 30, 2023
Abate by
Feb 9, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.109(j)(2)(ii):Small arms ammunition were not separated from flammable liquids, flammable solids as classified in 49 CFR part 172, and from oxidizing materials, by a fire-resistive wall of 1-hour rating or by a distance of 25 feet.  (a) BUILDING 3 BORTAC STORAGE- CN grenades, instantaneous grenades, and white star parachute flares were stored improperly amongst flammable materials exposing warehouse workers to potential smoke inhalation and burns.
Recent events (1)
  • — Z (S) $0

1910.178 L01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 30, 2023
Abate by
Feb 9, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(1)(ii):The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck. (a)	WAREHOUSE- Electric pallet jacks were being used to move loads, exposing employees to crush by hazards.
Recent events (1)
  • — Z (S) $0

1910.244 A01 II

Serious Gravity 5 1 instance 20 exposed
Issued
Jan 30, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.244(a)(1)(ii):Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means:  (a)	GARAGE, BAY 8- A floor jack was not labeled to identify its loading capacity, exposing employees to crushed by injuries.
Recent events (1)
  • — Z (S) $0

1910.305 G01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 30, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(i):Flexible cords and cables were not approved for conditions of use and location:  (a)	GARAGE, BAY 7- A 12-gauge extension cord with a SJTW rating was laying in oil under a work mat, and it was not rated for use in oily conditions, exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 6 instances 10 exposed
Issued
Jan 30, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) GARAGE,  ROOM 1027 -  The cord on the droplight had a damaged outer jacket, exposing mechanics to potential electric shock. b)GARAGE, BAY 6 - The cord on the droplight had a separated outer jacket, exposing mechanics to potential electric shock. c) GARAGE, BAY 6 - The blue droplight had a missing the bulb cover, exposing mechanics to potential electric shock. d) GARAGE, BAY 4 - The yellow extension cord had a separated outer jacket, exposing mechanics to potential electric shock. e) GARAGE, NEXT TO BAY 4 - The Miller welder cord had a separated outer jacket, exposing mechanics to potential electric shock. f) GARAGE, BAY 4 - The power cord to the automotive lift had a separated outer jacket, exposing mechanics to potential electric shock.
Recent events (1)
  • — Z (S) $0

View U.S. Border Patrol - Tucson Sector's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346338825.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.