TUCSON, AZ —
OSHA Inspection: U.S. BORDER PATROL - TUCSON SECTOR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. BORDER PATROL - TUCSON SECTOR in ATTEN: CHRISTOPHER KOEHLER 2430 S SWAN ROAD, TUCSON, AZ 85711 (NAICS 561210). OSHA activity number 346338825.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. BORDER PATROL - TUCSON SECTOR
- Site address
- ATTEN: CHRISTOPHER KOEHLER 2430 S SWAN ROAD
- City
- TUCSON
- State
- AZ
- ZIP
- 85711
- Mailing
- ATTEN: SAFETY 2430 S SWAN ROAD, TUCSON, AZ 85711
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- Employees
- 350
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.22 B
- Issued
- Jan 30, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b):29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface. (a) WAREHOUSE BREAK AREA- The break area located above the office exceeded the posted load rating of the mezzanine, exposing employees to injuries from the level collapsing. (b) WAREHOUSE- The load rating for the storage shelving above employee work areas had not been determined, exposing employees to injuries from the shelving collapsing. (c) BORTAC STORAGE- The load rating of the mezzanine had not been determined, exposing employees to injuries from the level collapsing.
Recent events (1)
- — Z (S) $0
1910.37 A01
- Issued
- Jan 30, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(1): The evacuation route contained hazardous and or flammable chemicals; or in the alternative 29 CFR 1910.106(d)(5)(i):Flammable liquids were stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people. (a) GARAGE, ROOM 1020- The hallway leading to the emergency exit door was lined with flammable cabinets and flammable storage, exposing employees to burns.
Recent events (1)
- — Z (S) $0
1910.37 B02
- Issued
- Jan 30, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit": (a) GARAGE, ROOM 1020- The storage area did not have marked and visible emergency exit.
Recent events (1)
- — Z (S) $0
1910.101 B
- Issued
- Jan 30, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: (a) WAREHOUSE MUNTIONS STORAGE: Two cylinders of carbon dioxide were stored without being secured against tipping/falling, exposing employees to injuries from projectiles. (b) WAREHOUSE MUNITIONS STORAGE: A cylinder of carbon dioxide was stored with without a valve protection cap on, exposing employees to injuries from projectiles.
Recent events (1)
- — Z (S) $0
1910.109 J02 II
- Issued
- Jan 30, 2023
- Abate by
- Feb 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.109(j)(2)(ii):Small arms ammunition were not separated from flammable liquids, flammable solids as classified in 49 CFR part 172, and from oxidizing materials, by a fire-resistive wall of 1-hour rating or by a distance of 25 feet. (a) BUILDING 3 BORTAC STORAGE- CN grenades, instantaneous grenades, and white star parachute flares were stored improperly amongst flammable materials exposing warehouse workers to potential smoke inhalation and burns.
Recent events (1)
- — Z (S) $0
1910.178 L01 II
- Issued
- Jan 30, 2023
- Abate by
- Feb 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(ii):The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck. (a) WAREHOUSE- Electric pallet jacks were being used to move loads, exposing employees to crush by hazards.
Recent events (1)
- — Z (S) $0
1910.244 A01 II
- Issued
- Jan 30, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(1)(ii):Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means: (a) GARAGE, BAY 8- A floor jack was not labeled to identify its loading capacity, exposing employees to crushed by injuries.
Recent events (1)
- — Z (S) $0
1910.305 G01 I
- Issued
- Jan 30, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(i):Flexible cords and cables were not approved for conditions of use and location: (a) GARAGE, BAY 7- A 12-gauge extension cord with a SJTW rating was laying in oil under a work mat, and it was not rated for use in oily conditions, exposing employees to electrical hazards.
Recent events (1)
- — Z (S) $0
1910.334 A02 II
- Issued
- Jan 30, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) GARAGE, ROOM 1027 - The cord on the droplight had a damaged outer jacket, exposing mechanics to potential electric shock. b)GARAGE, BAY 6 - The cord on the droplight had a separated outer jacket, exposing mechanics to potential electric shock. c) GARAGE, BAY 6 - The blue droplight had a missing the bulb cover, exposing mechanics to potential electric shock. d) GARAGE, BAY 4 - The yellow extension cord had a separated outer jacket, exposing mechanics to potential electric shock. e) GARAGE, NEXT TO BAY 4 - The Miller welder cord had a separated outer jacket, exposing mechanics to potential electric shock. f) GARAGE, BAY 4 - The power cord to the automotive lift had a separated outer jacket, exposing mechanics to potential electric shock.
Recent events (1)
- — Z (S) $0
More inspections at U.S. Border Patrol - Tucson Sector
View U.S. Border Patrol - Tucson Sector's full OSHA safety record →
More inspections in this industry (NAICS 561210)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346338825.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.