ENNIS, TX —
OSHA Inspection: SCHIRM USA INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCHIRM USA INC. in 2801 S. OAK GROVE DR., ENNIS, TX 75119 (NAICS 325320). OSHA activity number 346342108.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCHIRM USA INC.
- Site address
- 2801 S. OAK GROVE DR.
- City
- ENNIS
- State
- TX
- ZIP
- 75119
- Mailing
- P. O. BOX 237, ENNIS, TX 75120
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325320
- Employees
- 250
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.134 H03 I B
- Issued
- Apr 10, 2023
- Abate by
- May 8, 2023
- Penalty
- Initial $8,929 · Current $5,357 Reduced
General-duty citation text
29 CFR 1910.134(h)(3)(i)(B): Respirators maintained for use in emergency situations were not inspected at least monthly and in accordance with manufacturer recommendations. On November 10, 2022, and time prior thereto, the employer did not inspect, at least monthly, respirators maintained for use by employees in emergency situations. A bottled air-supplied respirator located outdoors adjacent to the isopropylamine (or IPA) bulk tank was not inspected monthly.
Recent events (2)
- — I (S) $5357.4
- — Z (S) $8929
1910.134 H03 III
- Issued
- Apr 10, 2023
- Abate by
- May 8, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(3)(iii): Self-contained breathing apparatus was not inspected monthly. On November 10, 2022, and times prior thereto, the employer did not inspect the following self-contained breathing apparatus (SCBA) monthly, did not maintain air and oxygen cylinders in a fully charged state and did not determine that the regulator and warning devices function properly. Ridgid cylinder and valve assembly Self-Contained Breathing Apparatus (SCBA) bottled air-supplied cylinder located outdoors adjacent to the isopropylamine tank was not inspected monthly exposing employees to hygroscopic colorless liquid with ammonia-like odor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H03 IV
- Issued
- Apr 10, 2023
- Abate by
- May 8, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(3)(iv): 29 CFR 1910.134(h)(3)(iv): For respirators maintained for emergency use, the employer did not [A] Certify the respirator by documenting the date the inspection was performed, the name (or signature) of the person who made the inspection, the findings, required remedial action, and the serial number or other means of identifying the inspected respirator; and [B] Provide this information on a tag or label that is attached to the storage compartment for the respirator, is kept with the respirator, or is included in the inspection reports stored as paper or electronic files. This information shall be maintained until replaced following a subsequent certification. On November 10, 2022, and times prior thereto, Schirm USA, Inc. did not certify respirators, maintained for emergency use, by documenting: date the inspection was performed, the name (or signature) of the person who made the inspection, the findings, required remedial action, and a serial number or other means of identifying the inspected respirator; and did not provide this information on a tag or label that is attached to the storage compartment for the respirator, is kept with the respirator, or is included in inspection reports stored as paper or electronic files. Ridgid cylinder and valve assembly Self-Contained Breathing Apparatus (SCBA) bottled air-supplied cylinder located outdoors adjacent to the isopropylamine tank was not inspected monthly exposing employees to hygroscopic colorless liquid with ammonia-like odor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Apr 10, 2023
- Penalty
- Initial $1,065 · Current $639 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. On November 10, 2022, and times prior thereto, at reactor tank number 2, the employer did not ensure fire extinguishers were identified with a fire extinguisher sign and ready accessible for employees exposing to fire and smoke hazards. a) Fire extinguisher sign missing on the west side lower deck of the reactor tank, b) Fire extinguisher sign missing above the west upper deck at the reactor tank.
Recent events (2)
- — I (O) $639
- — Z (O) $1065
More inspections at Schirm USA INC.
View Schirm USA INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325320)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346342108.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.