WATERVILLE, ME —
OSHA Inspection: HUHTAMAKI, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HUHTAMAKI, INC. in 242 COLLEGE AVENUE, WATERVILLE, ME 04901 (NAICS 322299). OSHA activity number 346351083.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HUHTAMAKI, INC.
- Site address
- 242 COLLEGE AVENUE
- City
- WATERVILLE
- State
- ME
- ZIP
- 04901
- Mailing
- 242 COLLEGE AVENUE, WATERVILLE, ME 04901
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322299
- Employees
- 594
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D06
- Issued
- Jan 31, 2023
- Penalty
- Initial $10,436 · Current $7,305 Reduced
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished. Chinet Mixer Area - The employer did not ensure employees performing repair work on a mixer pump used a means for verifying the equipment power was isolated and deenergized appropriately.
Recent events (2)
- — I (S) $7305.2
- — Z (S) $10436
1910.147 C06 II
- Issued
- Jan 31, 2023
- Abate by
- Mar 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection. Establishment - The employer did not ensure certification of periodic inspection included identifying the machine or equipment on which the energy control procedure was being utilized.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Huhtamaki, INC.
View Huhtamaki, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322299)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346351083.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.