Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HUHTAMAKI, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HUHTAMAKI, INC. in 242 COLLEGE AVENUE, WATERVILLE, ME 04901 (NAICS 322299). OSHA activity number 346351083.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Huhtamaki, INC. — free Get an email when a new federal OSHA severe-injury report for Huhtamaki, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HUHTAMAKI, INC.
Site address
242 COLLEGE AVENUE
City
WATERVILLE
State
ME
ZIP
04901
Mailing
242 COLLEGE AVENUE, WATERVILLE, ME 04901
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
594
Ownership type
A

2 citations on file for this inspection.

1910.147 D06

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2023
Penalty
Initial $10,436 · Current $7,305 Reduced
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished.  Chinet Mixer Area - The employer did not ensure employees performing repair work on a mixer pump used a means for verifying the equipment power was isolated and deenergized appropriately.
Recent events (2)
  • — I (S) $7305.2
  • — Z (S) $10436

1910.147 C06 II

Other-than-serious 1 instance 3 exposed
Issued
Jan 31, 2023
Abate by
Mar 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection.  Establishment - The employer did not ensure certification of periodic inspection included identifying the machine or equipment on which the energy control procedure was being utilized.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Huhtamaki, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346351083.