Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VISION AIR HVAC INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VISION AIR HVAC INC in 1050 35TH LN, PUEBLO, CO 81006 (NAICS 332312). OSHA activity number 346353907.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vision AIR Hvac INC — free Get an email when a new federal OSHA severe-injury report for Vision AIR Hvac INC is published. One employer, no account, unsubscribe in one click.
Establishment
VISION AIR HVAC INC
Site address
1050 35TH LN
City
PUEBLO
State
CO
ZIP
81006
Mailing
35 NORTH LASER STREET, PUEBLO WEST, CO 81007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.503 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 8, 2023
Abate by
Feb 28, 2023
Penalty
Initial $7,813 · Current $5,000 Reduced
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   (a) Vision Air HVAC Inc. DBA Vision Mechanical at 1050 35th LN Pueblo, CO 81006: On or before 11/21/22 the employer did not provide fall protection training to all employees who are or could be exposed to fall hazards. Employees installing ductwork on the roof of a commercial building were exposed to fall hazards associated with working in close proximity to an unguarded skylight cover, skylight roof openings, and roof perimeter fall hazards. This condition exposed employees to fall hazards greater than 13 feet.  Abatement Note: Abatement certification and documentation are required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7813

1926.501 B04 I

Repeat Gravity 10 1 instance 3 exposed
Issued
Feb 8, 2023
Abate by
Feb 28, 2023
Penalty
Initial $116,022 · Current $108,000 Reduced
29 CFR  1926.501(b)(4)(i):Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:  (a) Vision Air HVAC Inc. DBA Vision Mechanical at 1050 35th LN Pueblo, CO 81006: On or before 11/21/22 Vision Air HVAC Inc. DBA Vision Mechanical failed to protect employees from injury in that employees did not use personal fall arrest systems or other acceptable means of fall protection or guarding for two skylights on the first level of roof at the Pueblo County High School. An employee fell through an unguarded skylight, constructed of a 1/8" translucent bubble made of Plexiglas or similar, and fell 13'2" onto the concrete floor beneath. Two employees then removed the bubbles and installed rigid, permanent covers over both skylight openings without using a fall protection system. These conditions exposed employees to fall hazards greater than 13 feet.  Abatement Note: Abatement certification and documentation are required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (R) $108000
  • — Z (W) $116022

1926.501 B01

Repeat Gravity 10 1 instance 3 exposed
Issued
Feb 8, 2023
Abate by
Feb 28, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:   (a) Vision Air HVAC Inc. DBA Vision Mechanical at 1050 35th LN Pueblo, CO 81006: On or before 11/21/22 Vision Air HVAC Inc. DBA Vision Mechanical failed to  protect employees from injury in that the employer did not require the use of fall arrest systems or other acceptable means of fall protection while employees were hand-hoisting ductwork with a rope at the edge of the roof on the 1st and 2nd floors of a commercial building. This condition exposed employees to fall hazards greater than 10 feet.  Abatement Note: Abatement certification and documentation are required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (R) $0
  • — Z (W) $0

View Vision AIR Hvac INC's full OSHA safety record →