ERIE, PA —
OSHA Inspection: WABTEC US RAIL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WABTEC US RAIL, INC. in 2901 EAST LAKE ROAD, ERIE, PA 16531 (NAICS 336510). OSHA activity number 346392418.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WABTEC US RAIL, INC.
- Site address
- 2901 EAST LAKE ROAD
- City
- ERIE
- State
- PA
- ZIP
- 16531
- Mailing
- 2901 EAST LAKE ROAD, ERIE, PA 16531
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336510
- Employees
- 1956
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.132 D01
- Issued
- Feb 1, 2023
- Abate by
- Feb 28, 2023
- Penalty
- Initial $6,027 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.132(d)(1) The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: a.) Wabtec Freight Rail, Inc, Building, December 7, 2022 and times prior thereto: Using a crane, an employee removed a Stator with Roll Plate attached to it from a 170 degrees Celsius oven. Due to a misconfiguration of the part when assembled, while removing the bolts and screws that attached roll plates to the stator, the plate fell on the employee. A hazard assessment had been completed and the hazard of contact with the hot object was identified, but employer did not select and require Personal Protective Equipment designed to prevent thermal burns to the lower body, or otherwise implement a control to prevent against such contact, due to the unforeseen nature of incident. The employee sustained a second degree burn to the leg. b.) Wabtec Freight Rail, Inc, Building 6, 12/15/22 and times prior thereto: Employees in the Vacuum Pressure Impregnation (VPI) process were observed working without proper personal protective equipment for the thermal hazards presented by equipment including but not limited to, the roll plates and stators that were removed from the 170 degrees Celsius oven. Employees were noted to be wearing short sleeve shirts and standard workwear shirts with no thermal protective properties. (Deleted) ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $2000
- — Z (S) $6027
1910.179 G01 V
- Issued
- Feb 1, 2023
- Penalty
- Initial $6,027 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: a.) Wabtec Freight Rail, Inc, Building 6, 12/07/22 and times prior thereto: Directional buttons on remote control crane ID #A0027055B were unable to be read due to an accumulation of varnish on the device. Crane remote was used to lift equipment including but limited to GEB16 Stator with roll plate. NO ABATEMENT CERTIFICATION OR DOCUMENATION REQUIRED
Recent events (2)
- — I (S) $6000
- — Z (S) $6027
1910.179 J02 I
- Issued
- Feb 1, 2023
- Abate by
- Feb 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(i):Frequent crane inspections were not completed on all functioning operating mechanisms for maladjustment interfering with proper operation. a.) Wabtec Freight Rail, Inc, Building 6, 12/07/22 and times prior thereto: Daily inspections completed by operators did not identify that directional buttons on remote control crane ID #A0027055B were unable to be read due to an accumulation of varnish on the device. Crane remote was used to lift equipment including but limited to GEB16 Stator with roll plate. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Wabtec US Rail, INC.
View Wabtec US Rail, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336510)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346392418.