Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STRYTEN ENERGY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STRYTEN ENERGY in 714 EAST KEEFE AVE., MILWAUKEE, WI 53212 (NAICS 326199). OSHA activity number 346392681.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stryten Energy — free Get an email when a new federal OSHA severe-injury report for Stryten Energy is published. One employer, no account, unsubscribe in one click.
Establishment
STRYTEN ENERGY
Site address
714 EAST KEEFE AVE.
City
MILWAUKEE
State
WI
ZIP
53212
Mailing
714 EAST KEEFE AVE., MILWAUKEE, WI 53212
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
120
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Deleted Serious Gravity 5 4 instances 8 exposed
Issued
Apr 28, 2023
Abate by
May 17, 2023
Penalty
Initial $6,831 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    (a) On or about December 12, 2022, the machine specific procedure for Cold Form Machine 1 did not include gravitational energy sources and steps to isolate gravitational energy sources, exposing employees to  caught-in, struck-by and amputation hazard.  (a) On or about December 12, 2022, the machine specific procedure for Cold Form Machine 2 did not include gravitational energy sources and steps to isolate gravitational energy sources, exposing employees to  caught-in, struck-by and amputation hazard.  (a) On or about December 12, 2022, the machine specific procedure for Cold Form Machine 3 did not include gravitational energy sources and steps to isolate gravitational energy sources, exposing employees to  caught-in, struck-by and amputation hazard.  (a) On or about December 12, 2022, the machine specific procedure for Cold Form Machine 4 did not include gravitational energy sources and steps to isolate gravitational energy sources, exposing employees to  caught-in, struck-by and amputation hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $6831
  • — Z (S) $6831

1910.147 C07 III B

Serious Gravity 5 4 instances 8 exposed
Issued
Apr 28, 2023
Abate by
May 17, 2023
Penalty
Initial $8,539 · Current $11,500
29 CFR 1910.147(c)(7)(iii)(B) Additional retraining shall also be conducted whenever a periodic inspection under paragraph (c)(6) of this section reveals, or whenever the employer has reason to believe that there are deviations from or inadequacies in the employee's knowledge or use of the energy control procedures.   (a) On or about December 12, 2022, an employee was unjamming the tail grabber assembly of the Cold Form Machine 1. The Cold Form Machine 1 was not deenergized, locked out, and the tail grabber assembly was not blocked to prevent the tail grabber from sliding down back into the start position. This exposed the employee to a struck-by and crushing hazard.  The employer failed to implement energy control application steps as the machine was not isolated from all energy sources [per the 1910.147(d)(3) requirements]. As a result, the remaining applicable energy control elements, involving LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards.