Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OLLIE'S BARGAIN OUTLET, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OLLIE'S BARGAIN OUTLET, INC. in 3300 EXPRESSO WAY, YORK, PA 17406 (NAICS 493110). OSHA activity number 346401433.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ollie'S Bargain Outlet, INC. — free Get an email when a new federal OSHA severe-injury report for Ollie'S Bargain Outlet, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3300 EXPRESSO WAY
City
YORK
State
PA
ZIP
17406
Mailing
3300 EXPRESSO WAY, YORK, PA 17406
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
225
Ownership type
A

23 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 7 instances 40 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $9,822 · Current $11,248
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees due to exposure to struck by hazards.  c. The Warehouse - On or about December 20, 2022, the rack location 7801B002 was spot loaded on the grate and the grate was collapsing in due to the weight, exposing employees to struck by hazards.   e. The Warehouse - On or about December 20, 2022, the rack location 7727B055 was spot loaded on the grate and the grate was bending upward due to the weight, exposing employees to struck by hazards.   f. The Warehouse - On or about December 20, 2022, the rack location 4255B111, the connector was not engaged into the rack system creating an unstable load, exposing employees to struck by hazards.  a. Warehouse - On or about December 20, 2022, employees were exposed to struck by hazards from unstable storage as the pallet of Maples Rugs in location 78-02-B003 was hanging out of the rack system.  b. Bulk Storage - On or about December 20, 2022, the Sterilite pallets were stacked 3 high, the bottom pallet was damaged which caused for the load to be leaning, employees were exposed to a struck by hazard.   c. Bulk Storage - On or about December 20, 2022, the top pallet of the EMP Scandia Oaknord was leaning due to broken pallet and hanging off the lower tiers, employees were exposed to a struck by hazard.   d. Bulk Storage - On or about December 20, 2022, the stacking frame of rugs 419127 was missing a stanchion causing materials to hang out exposing employees to a struck by hazard.   e. Bulk Storage - On or about December 20, 2022, the stacking frames 7149A098, 4734A069, 6548AL95, 6527A053, were not set properly causing the loads to be unstable, employees were exposed to a struck by hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $11248
  • — Z (S) $9822

1910.22 A03

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $9,822 · Current $9,822
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  a. Warehouse - On or about December 20, 2022, employees would walk across a 34" wide roll conveyor that had a fixed ladder access on either side for entry and egress, employees were exposed to a fall hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $9822
  • — Z (S) $9822

1910.28 B03 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 15, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(3)(iv):  The employer did not provide that each employee be protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used.  a. Outbound - On or about December 20, 2022, employees were observed working on the conveyor system catwalk over the outbound loading areas, the ladder access to the catwalk did not have a self-closing gate, employees were exposed to a fall hazard.  b. Pump Room - On or about December 20, 2022, employees access the top of the maintenance shop using a fixed ladder that doesn't have a self-closing gate at the top, employees are exposed to fall hazards.    Corrected During Inspection
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 F02 II

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Jun 15, 2023
Abate by
Jun 28, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.110(f)(2)(ii): Liquefied petroleum gas container(s) stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people:  a. Man Door 23 - On or about December 20, 2022, employees were exposed to fire hazard due to the employer having stored liquified petroleum gas tanks two feet from the exit door on the outside.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 15, 2023
Abate by
Jul 6, 2023
Penalty
Initial $9,822 · Current $9,822
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a. Maintenance - On or about December 20, 2022, the employer failed to develop and implement a lockout tagout program, to include but not limited procedures, periodic inspections, implementation, enforcement, and uniformity, employees were exposed to reenergization hazards to include caught in and electrical.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $9822
  • — Z (S) $9822

1910.132 D01

Deleted Serious Gravity 1 1 instance 225 exposed
Issued
Jun 15, 2023
Abate by
Jun 28, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE).  a. Warehouse - On or about December 20, 2022, the employer failed to perform a work hazard assessment to determine the necessary PPE to protect employees from struck by hazards, flyings and other injuries.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C01

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 15, 2023
Abate by
Jun 28, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  a. Distribution Center - On or about December 20, 2022, the employer failed to evaluate the workplace to determine if any permit required confined spaces were present in the workplace, to include but not limited dock levelers for maintenance, sump pump pits, and sewer pits. Employees and contractors were exposed to atmospheric and mechanical hazards.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 1 1 instance 40 exposed
Issued
Jun 15, 2023
Abate by
Jul 6, 2023
Penalty
Initial $7,366 · Current $7,366
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a. Warehouse - On or about December 20, 2022, employees were operating powered industrial vehicles without having performed evaluations on a three-year basis, exposing employees to a struck by hazard.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $7366
  • — Z (S) $7366

1910.212 A01

Serious Gravity 5 4 instances 30 exposed
Issued
Jun 15, 2023
Abate by
Jun 30, 2023
Penalty
Initial $9,822 · Current $9,822
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a. Shipping Door 124 - On or about December 20, 2022, employees were exposed to a caught in hazard from unguarded roll conveyor three belt drive system that was between 60 inches and up to beyond 7 feet.   b. Shipping Door 120 - On or about December 20, 2022, employees were exposed to a caught in hazard from unguarded roll conveyor three belt drive system that was between 60 inches and up to beyond 7 feet.   c. Shipping Door 118 - On or about December 20, 2022, employees were exposed to a caught in hazard from unguarded roll conveyor three belt drive system that was between 60 inches and up to beyond 7 feet.   d. Shipping Door 106 - On or about December 20, 2022, employees were exposed to a caught in hazard from unguarded roll conveyor three belt drive system that was between 60 inches and up to beyond 7 feet.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $9822
  • — Z (S) $9822

1910.303 B02

Serious Gravity 1 3 instances 15 exposed
Issued
Jun 15, 2023
Abate by
Jun 28, 2023
Penalty
Initial $7,366 · Current $7,366
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. Battery Charging Area - On or about December 20, 2022, there were six hanging receptacle boxes with knock outs in the battery area were being used as a pendant against listing and labeling, employees were exposed to an electrical hazard.  b. Maintenance shop - On or about December 20, 2022, the employees were exposed to electrical hazards from using a relocatable power tap against listing and labeling to power a bench grinder.   c. OAS3-DR-0P - On or about December 20, 2022, the relocatable power tap was being used in an industrial environment against listing and labeling which showed signs of having an arcing event, exposing employees to electrical hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $7366
  • — Z (S) $7366

1910.303 B03

Serious Gravity 1 2 instances 15 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(3): Insulation Integrity. Complete wiring installations were not free from short circuits and from grounds.  a. Inbound Door 1 - On or about December 20, 2022, there was uninsulated conductor wires that had been wired into the Class 2 transformer plug for an Inovonics sensor, employees were exposed to an electrical hazard.  b. Inbound Door 22 - On or about December 20, 2022, there was uninsulated conductor wires that had been wired into the Class 2 transformer plug for an Inovonics sensor, employees were exposed to an electrical hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 2 instances 20 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $7,366 · Current $7,366
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a. Man Door 14 - On or about December 20, 2022, extension cords were used as a substitute for fixed wiring, the employer had run it up the wall to the top height of the doors, zip tied it to a beam and ran it over to another door, exposing employees to an electrical fire hazard.   b. Door 114 - On or about December 20, 2022, an extension cord was used as a substitute for fixed wiring, the employer had routed an extension cord up over a beam then ran it over to the overhead roll conveyor where it was zip tied and then down to the controls for the M.J. Mallis, employees were exposed to an electrical hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $7366
  • — Z (S) $7366

1910.305 G01 IV C

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows or floors.  a. Door 35 - On or about December 20, 2022, the flexible extension cord was routed through the overhead door 38 and then was pinched in the truck door of truck 1776865, employees were exposed to an electrical hazard.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 3 instances 20 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a. Door 35 - On or about December 20, 2022, the flexible extension cord was routed through the overhead door 38 and then was pinched in the truck door of truck 1776865 had pulled strain relief at the plug head, employees were exposed to an electrical hazard.  b. Door 38 - On or about December 20, 2022, the flexible cord for the door light had a replacement plug head with pulled strain relief, employees were exposed to an electrical hazard.  c. Shipping - On or about December 20, 2022, the flexible power charging cord for the Toyota EJ031 had pulled strain relief from the plug head, employees were exposed to an electrical hazard.  d. Door 124 - On or about December 20, 2022, the strain relief was pulled from the junction box for the conveyor, employees were exposed to an electrical hazard.  e. Battery Charging Area - On or about December 20, 2022, the battery charging cable plugged into receptacle RCH-3 #21 had pulled strain relief, employees were exposed to an electrical hazard.   f. Battery Charging Area - On or about December 20, 2022, the battery charging cable plugged into receptacle BCH1 #15 had pulled strain relief, employees were exposed to an electrical hazard.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Deleted Serious Gravity 1 1 instance 10 exposed
Issued
Jun 15, 2023
Abate by
Jun 30, 2023
Penalty
Initial $7,366 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a. Outbound Control Center - On or about December 20, 2022, combustible materials were stored on top of the dry type transformer exposing employees to a fire hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7366

1910.305 D02

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 15, 2023
Abate by
Jun 28, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets that were dead front:  a. Outbound Control Center - On or about December 20, 2022, cabinet LP-CP2 was not fully dead front as the lower section typically reserved for the main shutoff was open showing the terminal wires and giving full access to live components, employees were exposed to an electrical hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A01

Serious Gravity 5 4 instances 40 exposed
Issued
Jun 15, 2023
Abate by
Jun 28, 2023
Penalty
Initial $9,822 · Current $9,822
29 CFR 1910.334(a)(1): Portable electric equipment was not handled in a manner which would not cause damage:  a. Inbound - On or about December 20, 2022, the Toyota E0004 electric pallet jack had a damaged charging cord, employees were exposed to electrical hazards.  b. Door 12 - On or about December 20, 2022, the dock door trailer light had damage to the cord jacket, employees were exposed to electrical hazards.  c. Door 38 - On or about December 20, 2022, the dock door trailer light had damage to the cord jacket, employees were exposed to electrical hazards.  d. Outbound - On or about December 20, 2022, the Toyota EJ03 cord was damaged to the point of exposed copper wiring, employees were exposed to electrical hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $9822
  • — Z (S) $9822

1910.334 A03 I

Serious Gravity 5 4 instances 15 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(i): A flexible cord used with the type of ground equipment did not contain an electrical equipment grounding conductor.  a. Door 1 - On or about December 20, 2022, the dock light cord used to facilitate inspection of the trailer and offloading of materials was missing the grounding conductor (pin), employees were exposed to an electrical hazard.  b. Between Door 5 and 6 - On or about December 20, 2022, the dock light cord used to facilitate inspection of the trailer and offloading of materials was missing the grounding conductor (pin), employees were exposed to an electrical hazard.  c. Door 16 - On or about December 20, 2022, the dock light cord used to facilitate inspection of the trailer and offloading of materials was missing the grounding conductor (pin), employees were exposed to an electrical hazard.  d. Door 22 - On or about December 20, 2022, the dock light cord used to facilitate inspection of the trailer and offloading of materials was missing the grounding conductor (pin), employees were exposed to an electrical hazard.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 B

Deleted Repeat Gravity 5 5 instances 20 exposed
Issued
Jun 15, 2023
Abate by
Jun 28, 2023
Penalty
Initial $49,110 · Current $0 Reduced
29 CFR 1910.176(b): The storage of material shall not create a hazard. Items such as bags, containers, bundles, etc., were not stored in tiers and stacked, blocked, interlocked and limited in height so that they were stable and secure against sliding or collapse.  a. Warehouse - On or about December 20, 2022, employees were exposed to struck by hazards from unstable storage as the pallet of Maples Rugs in location 78-02-B003 was hanging out of the rack system.  b. Bulk Storage - On or about December 20, 2022, the Sterilite pallets were stacked 3 high, the bottom pallet was damaged which caused for the load to be leaning, employees were exposed to a struck by hazard.   c. Bulk Storage - On or about December 20, 2022, the top pallet of the EMP Scandia Oaknord was leaning due to broken pallet and hanging off the lower tiers, employees were exposed to a struck by hazard.   d. Bulk Storage - On or about December 20, 2022, the stacking frame of rugs 419127 was missing a stanchion causing materials to hang out exposing employees to a struck by hazard.   e. Bulk Storage - On or about December 20, 2022, the stacking frames 7149A098, 4734A069, 6548AL95, 6527A053, were not set properly causing the loads to be unstable, employees were exposed to a struck by hazard.  Ollie's Bargain Outlet, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.176(b), which was contained in OSHA inspection number 1542838, citation number 1, item number 2b and was affirmed as a final order on 02/09/2022, with respect to a workplace located at 1523 Steve Reynolds Industrial Pkwy, Commerce, GA 30529.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (R) $0
  • — Z (R) $49110

1910.305 B01 II

Other-than-serious 2 instances 10 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a. Door 106 - On or about December 20, 2022, the junction box for the shipping conveyor had an unused opening.  b. Door 121 - On or about December 20, 2022, the junction box for the shipping conveyor had an unused opening.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.22 B

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface.  a. Pump Room - On or about December 20, 2022, materials were stored on top of the pump room which was not marked with a load rating to identify the limits to prevent collapse of materials or personnel, exposing employees to fall and struck by hazards.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.37 A03

Other-than-serious Gravity 1 2 instances 40 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $7,366 · Current $7,366
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a. Man Door 23 - On or about December 20, 2022, there was a fence and key controlled gate that prevented access to man door 23 which was identified as an emergency exit, employees were exposed to fire egress hazards.   b. Maintenance - On or about December 20, 2022, exit door A4 was blocked by a dumpster, floor sweep roll and various other maintenance tools, employees were exposed to fire egress hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $7366
  • — Z (S) $7366

1910.215 B09

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Jun 15, 2023
Abate by
Sep 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a. Maintenance - On or about December 20, 2022, employees were exposed to struck by hazards due to operating a DeWalt DW758 bench grinder that did not have the tongue guard set to within the periphery to less than 1/4."  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)