PHILADELPHIA, PA —
OSHA Inspection: A SQUARED CONSTRUCTION LLC DBA A SQUARED FRAMING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A SQUARED CONSTRUCTION LLC DBA A SQUARED FRAMING in 1901 E YORK ST, PHILADELPHIA, PA 19125 (NAICS 238130). OSHA activity number 346427925.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A SQUARED CONSTRUCTION LLC DBA A SQUARED FRAMING
- Site address
- 1901 E YORK ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19125
- Mailing
- 1430 GERMANTOWN AVE., PHILADELPHIA, PA 19122
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B02
- Issued
- Jun 29, 2023
- Abate by
- Jul 10, 2023
- Penalty
- Initial $12,031 · Current $12,031
General-duty citation text
29 CFR 1926.451(b)(2):Scaffold platforms and walkways were not at least 18 inches wide. a) Jobsite: 1901 E York St, Philadelphia, PA 19125- On or about January 10, 2023, the employer permitted employees to work from a supported tubular welded frame scaffold platform, approximately 9 ? inches in width, which was erected within an elevator shaft on the 6th level of a residential construction building, thereby exposing the employees to a fall hazard of approximately 60 feet.
Recent events (1)
- — Z (S) $12031
1926.451 E01
- Issued
- Jun 29, 2023
- Abate by
- Jul 10, 2023
- Penalty
- Initial $12,031 · Current $12,031
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Jobsite: 1901 E York St, Philadelphia, PA 19125 - On or about January 10, 2023, the employer did not provide a safe means of access to and from each level of a supported tubular welded frame scaffold, which was erected within the elevator shaft of a 6 story residential construction building, by the use of portable ladders, hook-on ladders or other acceptable means. Employees climbed the scaffold end frames on the 5th level of the building to access the 6th level of the building, which measured 7 feet above the walking working surface of the 5th level, and approximately 60 feet above the ground level through the elevator shaft opening.
Recent events (1)
- — Z (S) $12031
1926.503 A01
- Issued
- Jun 29, 2023
- Abate by
- Jul 12, 2023
- Penalty
- Initial $12,031 · Current $12,031
General-duty citation text
29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. a) Jobsite: 1901 E York St, Philadelphia, PA 19125 - On or about January 10, 2023, the employer did not provide a training program for each employee conducing framing activities on a residential building in the recognition and avoidance of fall hazards.
Recent events (1)
- — Z (S) $12031
1926.1053 A03 I
- Issued
- Jun 29, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $8,595 · Current $8,595
General-duty citation text
29 CFR 1926.1053(a)(3)(i):Rungs, cleats, and/or steps of portable ladders (except step stools) and/or fixed ladders (including individual-rung/step ladders) were spaced less than 10 inches (25 cm) apart or more than 14 inches (36 cm) apart, as measured a) Jobsite: 1901 E York St, Philadelphia, PA 19125 - On or about January 10, 2023, the employer permitted employees to use a job-made ladder with rungs that were spaced approximately 16 inches apart thus exposing employees to slip and fall hazards.
Recent events (1)
- — Z (S) $8595
1926.1053 B01
- Issued
- Jun 29, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $12,031 · Current $12,031
General-duty citation text
29 CFR 1926.1053(b)(1):Where ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) Jobsite: 1901 E York St, Philadelphia, PA 19125 - On or about January 10, 2023, the employer did not ensure the side rails of the job made ladder on the 5th level of a 6th story residential apartment building extended at least 3 feet above the upper landing surface of the 6th level thereby exposing employees using the ladder to access the 6th level to a slip and fall hazard of approximately 10 feet.
Recent events (1)
- — Z (S) $12031
1926.501 B13
- Issued
- Jun 29, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $60,156 · Current $60,156
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system. a) Jobsite: 1901 E York St, Philadelphia, PA 19125 - On or about January 10, 2023, the employer did not ensure employees conducting framing activities along open and unprotected sides and edges on the 6th level of a residential apartment building, approximately 60 feet above the ground level, were protected from the falls by the use of a fall protection system. A Squared Construction LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1599432, citation number 1, item number 1, and was affirmed as a final order on December 27, 2022, with respect to a workplace located at 2100 Lombard St, Philadelphia, PA 19146. A Squared Construction LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1491777, citation number 1, item number 1, and was affirmed as a final order on February 20, 2021, with respect to a workplace located at 2035 E Lehigh Ave, Philadelphia, PA 19130. A Squared Construction LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1434359, citation number 1, item number 1, and was affirmed as a final order on January 16, 2020, with respect to a workplace located at 1524 N. Philip St., Philadelphia, PA 19122.
Recent events (1)
- — Z (R) $60156
More inspections at A Squared Construction LLC DBA a Squared Framing
View A Squared Construction LLC DBA a Squared Framing's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346427925.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.