Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ILLINOIS TOOL WORKS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ILLINOIS TOOL WORKS INC. in 8125 COBB CENTER DRIVE, KENNESAW, GA 30152 (NAICS 325612). OSHA activity number 346441645.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Illinois Tool Works INC. — free Get an email when a new federal OSHA severe-injury report for Illinois Tool Works INC. is published. One employer, no account, unsubscribe in one click.
Site address
8125 COBB CENTER DRIVE
City
KENNESAW
State
GA
ZIP
30152
Mailing
8125 COBB CENTER DRIVE, KENNESAW, GA 30152
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325612
Employees
80
Ownership type
A

4 citations on file for this inspection.

1910.28 B01 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2023
Abate by
Aug 7, 2023
Penalty
Initial $8,349 · Current $8,349
29 CFR  1910.28(b)(1)(i):29 CFR 1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  a) Blending Department: On January 11, 2023, and at times prior, the employer exposed employees to fall hazards of approximately 7 feet, 7 inches, in that the employer did not ensure that the guardrails of the platform around the mask tank extended across all of its unprotected sides as employees accessed the platform to monitor the condition of the tank's chemical contents.
Recent events (2)
  • — I (O) $8349
  • — Z (S) $8349

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2023
Abate by
Aug 7, 2023
Penalty
Initial $8,349 · Current $6,000 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Wick Processing Department: On January 13, 2023, and at times prior, employer exposed employees to burn hazards from contact with temperatures of up to 263 degrees F, in that the employer did not develop and require employees to utilize energy-isolating procedures before entering vacuum oven of the Flux Machine to perform maintenance activities such as correcting wires that have become tangled or broken inside the equipment.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $8349

1910.212 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2023
Abate by
Aug 7, 2023
Penalty
Initial $12,523 · Current $0 Reduced
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   a) Wick Winding Department: On January 13, 2023, and at times prior, the employer exposed employees to amputation hazards, in that the light curtains installed on the wick winding machines are not sufficient for preventing the clamping mechanism from closing while the operator inserts their hand near the point of operation to place or remove wire bobbins.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12523

1910.303 B02

Serious Gravity 5 3 instances 1 exposed
Issued
Jul 10, 2023
Abate by
Aug 7, 2023
Penalty
Initial $8,349 · Current $5,000 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Wick Winding Department: On January 11, 2023, and at times prior, the employer exposed employees to electrical fire hazards, in that two power strips were connected to one another in order to supply power to equipment in the area, including the labeling machine at the center of the department as employees operate the machine.  b) Wick Winding Department: On January 11, 2023, and at times prior, employer exposed employees to fire and electrical shock hazards, in that the employer did not mount the metal electrical box powering the Labeling/Sealing Machine to a secure surface, instead using it as a pendant drop outlet box hanging above the machine as employees operate it.   c) Wick Winding Department: On January 11, 2023, and at times prior, the employer exposed employees to fire and electrical shock hazards, in that the employer did not mount the metal electrical box powering the Little David case sealer machine to a secure surface as employees operate the equipment.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $8349

View Illinois Tool Works INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346441645.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.