BEDFORD PARK, IL —
OSHA Inspection: CORRUGATED SUPPLIES COMPANY, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CORRUGATED SUPPLIES COMPANY, LLC in 5043 W. 67TH STREET, BEDFORD PARK, IL 60638 (NAICS 322211). OSHA activity number 346451875.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORRUGATED SUPPLIES COMPANY, LLC
- Site address
- 5043 W. 67TH STREET
- City
- BEDFORD PARK
- State
- IL
- ZIP
- 60638
- Mailing
- 5043 W. 67TH STREET, BEDFORD PARK, IL 60638
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 167
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Mar 17, 2023
- Penalty
- Initial $15,625 · Current $11,000 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. On or about January 17, 2023, in the Mac Daddy Production Area, employees were exposed to machine hazards associated with nip points when engaged in servicing and maintenance activities in the MAC Daddy Slitter Scorer's Switch Cabinet Number 12511. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.
Recent events (2)
- — I (O) $11000
- — Z (S) $15625
More inspections at Corrugated Supplies Company, LLC
View Corrugated Supplies Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346451875.