OSHA Inspection: CRESTONE GROUP, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CRESTONE GROUP, LLC in 800 INDUSTRIAL BLVD. STE 150, GRAPEVINE, TX 76051 (NAICS 311811). OSHA activity number 346462161.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crestone Group, LLC — free Get an email when a new federal OSHA severe-injury report for Crestone Group, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CRESTONE GROUP, LLC
Site address
800 INDUSTRIAL BLVD. STE 150
City
GRAPEVINE
State
TX
ZIP
76051
Mailing
800 INDUSTRIAL BLVD. STE 150, GRAPEVINE, TX 76051
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311811
Employees
65
Ownership type
A

8 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 7 exposed
Issued
Mar 23, 2023
Abate by
Apr 20, 2023
Penalty
Initial $14,063 · Current $8,438 Reduced
29 CFR  1910.147(c)(4)(ii):The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section.  On or about January 26, 2023, and times prior thereto , the energy control procedures did not include clearly and specifically outline the purpose.
Recent events (2)
  • — I (S) $8437.8
  • — Z (S) $14063

1910.147 C04 II B

Serious Gravity 10 37 instances 7 exposed
Issued
Mar 23, 2023
Abate by
Apr 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  On or about January 26, 2023, and times prior thereto, the provided energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machinery and/or equipment to control hazardous energy in the following instances below :  A)	Mixer Changeable Tool - 92, 217, 218 B)	Compact Line - 278 C)	Dough Press - 286 D)	Extreme Side Sealer - 344, 622 E)	Slicer - 348, 633, 685 F)	Depositor Vemag - 371 G)	Mixer Fixed Bowl - 442, 1241 H)	Mixer - 543 I)	Kettle - 527 J)	Lift Bowl - 545 K)	Ovens - 547, 548, 549, 550, 552, 553, 554, 555, 1044, 1045, 1046 L)	Oscar Line - 556 M)	Proof Box - 863, 864, 865 N)	Pallet Jack Toyota - 948 O)	Rheon - 1037 P)	Sprayer Pan - 1031 Q)	Slicer UBE - 1182 R)	Pallet Wrapper - 1186 S)	Vemag Robot 500 Depositor - 1200
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II D

Serious Gravity 10 1 instance 7 exposed
Issued
Mar 23, 2023
Abate by
Apr 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(D):The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.  On or about January 26, 2023, and times prior thereto, the provided energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.263 L09 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 23, 2023
Penalty
Initial $10,046 · Current $6,028 Reduced
29 CFR  1910.263(l)(9)(ii):All safety devices on the oven's were not inspected at intervals of not less than once a year by a representative of the oven manufacturer.  On or about January 26, 2023, and times prior thereto, All safety devices on the oven's were not inspected at intervals of not less than once a year by a representative of the oven manufacturer or another certified third party company.
Recent events (2)
  • — I (S) $6027.6
  • — Z (S) $10046

1910.263 L09 V B

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 23, 2023
Abate by
Apr 20, 2023
Penalty
Initial $10,046 · Current $6,028 Reduced
29 CFR  1910.263(l)(9)(v)(b):The safety shutoff valve for the gas fuel was not tested at least twice monthly.  On or about January 26, 2023, and times prior thereto, the safety shut off valves for the gas fuel supply for the ovens were not tested at least twice monthly by a trained company representative.
Recent events (2)
  • — I (S) $6027.6
  • — Z (S) $10046

1910.147 C05 II

Other-than-serious 3 instances 35 exposed
Issued
Mar 23, 2023
Abate by
Apr 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for other purposes than controlling energy for maintenance or repair purposes.   On or about January 26, 2023, and times prior thereto, equipment that was deemed to be out of service and not scheduled for repair, service, maintenance or replacement was locked out/tagged out long term in the following instances :  a) Automatic Door between Lamination Room and Main Production Area b) Oven Number 1 and 6 in the Oven Room c) Electrical Panel in Receiving Department on Sugar Bin switch
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C05 II D

Other-than-serious 2 instances 7 exposed
Issued
Mar 23, 2023
Abate by
Apr 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(5)(ii)(D):Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s)  On or about January 26, 2023, and times prior thereto, lockout devices did not indicate the identity of the of the employee who applied the device(s).  a) Oven Number 1 and 6 in the Oven Room b) Electrical Panel in Receiving Department on Sugar Bin switch
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 M05 II

Other-than-serious 2 instances 2 exposed
Issued
Mar 23, 2023
Abate by
Apr 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(m)(5)(ii): A powered industrial truck was left unattended when the operator is 25 ft. or more away from the vehicle which remains in view, or whenever the operator leaves the vehicle and it is not in view.  On or about January 26, 2023, and times prior thereto, powered industrial trucks were left unattended by their operator(s) during the following instances :   a) Crown Stand Up Lift in Shipping Department b) Crown Lift in Receiving Department
Recent events (2)
  • — I (O) $0
  • — Z (O) $0