GRAPEVINE, TX —
OSHA Inspection: CRESTONE GROUP, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CRESTONE GROUP, LLC in 800 INDUSTRIAL BLVD. STE 150, GRAPEVINE, TX 76051 (NAICS 311811). OSHA activity number 346462161.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRESTONE GROUP, LLC
- Site address
- 800 INDUSTRIAL BLVD. STE 150
- City
- GRAPEVINE
- State
- TX
- ZIP
- 76051
- Mailing
- 800 INDUSTRIAL BLVD. STE 150, GRAPEVINE, TX 76051
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311811
- Employees
- 65
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 II
- Issued
- Mar 23, 2023
- Abate by
- Apr 20, 2023
- Penalty
- Initial $14,063 · Current $8,438 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii):The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section. On or about January 26, 2023, and times prior thereto , the energy control procedures did not include clearly and specifically outline the purpose.
Recent events (2)
- — I (S) $8437.8
- — Z (S) $14063
1910.147 C04 II B
- Issued
- Mar 23, 2023
- Abate by
- Apr 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about January 26, 2023, and times prior thereto, the provided energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machinery and/or equipment to control hazardous energy in the following instances below : A) Mixer Changeable Tool - 92, 217, 218 B) Compact Line - 278 C) Dough Press - 286 D) Extreme Side Sealer - 344, 622 E) Slicer - 348, 633, 685 F) Depositor Vemag - 371 G) Mixer Fixed Bowl - 442, 1241 H) Mixer - 543 I) Kettle - 527 J) Lift Bowl - 545 K) Ovens - 547, 548, 549, 550, 552, 553, 554, 555, 1044, 1045, 1046 L) Oscar Line - 556 M) Proof Box - 863, 864, 865 N) Pallet Jack Toyota - 948 O) Rheon - 1037 P) Sprayer Pan - 1031 Q) Slicer UBE - 1182 R) Pallet Wrapper - 1186 S) Vemag Robot 500 Depositor - 1200
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- Mar 23, 2023
- Abate by
- Apr 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D):The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. On or about January 26, 2023, and times prior thereto, the provided energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.263 L09 II
- Issued
- Mar 23, 2023
- Penalty
- Initial $10,046 · Current $6,028 Reduced
General-duty citation text
29 CFR 1910.263(l)(9)(ii):All safety devices on the oven's were not inspected at intervals of not less than once a year by a representative of the oven manufacturer. On or about January 26, 2023, and times prior thereto, All safety devices on the oven's were not inspected at intervals of not less than once a year by a representative of the oven manufacturer or another certified third party company.
Recent events (2)
- — I (S) $6027.6
- — Z (S) $10046
1910.263 L09 V B
- Issued
- Mar 23, 2023
- Abate by
- Apr 20, 2023
- Penalty
- Initial $10,046 · Current $6,028 Reduced
General-duty citation text
29 CFR 1910.263(l)(9)(v)(b):The safety shutoff valve for the gas fuel was not tested at least twice monthly. On or about January 26, 2023, and times prior thereto, the safety shut off valves for the gas fuel supply for the ovens were not tested at least twice monthly by a trained company representative.
Recent events (2)
- — I (S) $6027.6
- — Z (S) $10046
1910.147 C05 II
- Issued
- Mar 23, 2023
- Abate by
- Apr 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for other purposes than controlling energy for maintenance or repair purposes. On or about January 26, 2023, and times prior thereto, equipment that was deemed to be out of service and not scheduled for repair, service, maintenance or replacement was locked out/tagged out long term in the following instances : a) Automatic Door between Lamination Room and Main Production Area b) Oven Number 1 and 6 in the Oven Room c) Electrical Panel in Receiving Department on Sugar Bin switch
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C05 II D
- Issued
- Mar 23, 2023
- Abate by
- Apr 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D):Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s) On or about January 26, 2023, and times prior thereto, lockout devices did not indicate the identity of the of the employee who applied the device(s). a) Oven Number 1 and 6 in the Oven Room b) Electrical Panel in Receiving Department on Sugar Bin switch
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 M05 II
- Issued
- Mar 23, 2023
- Abate by
- Apr 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(m)(5)(ii): A powered industrial truck was left unattended when the operator is 25 ft. or more away from the vehicle which remains in view, or whenever the operator leaves the vehicle and it is not in view. On or about January 26, 2023, and times prior thereto, powered industrial trucks were left unattended by their operator(s) during the following instances : a) Crown Stand Up Lift in Shipping Department b) Crown Lift in Receiving Department
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Crestone Group, LLC
View Crestone Group, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311811)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346462161.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.